Calibration Board

Calibration board is usually used for intrinsic parameter check and hand-eye calibration. This chapter introduces the types, models, and mounting methods of calibration boards.

Calibration Board Types and Models

Mech-Mind provides three types of calibration boards: BDB, CGB and OCB.

CGB

For V4 cameras.

Model Functional Diagrams d (mm) Row Column

CGB-020

calib diagram cgb

20

5

4

CGB-035

35

5

4

CGB-050

50

5

4

OCB

OCB calibration boards have no mounting holes and therefore cannot be mounted on the last joint of the robot. It can be used only when the camera is mounted in the eye in hand (EIH) mode.

Model Functional Diagrams d (mm) Row Column

OCB-005

calib diagram ocb

5

9

11

OCB-010

10

9

11

OCB-020

20

9

11

BDB

For V2 and V3 cameras.

Model Functional Diagrams d (mm) Row Column

BDB-5

calib diagram bdb

20

5

4

BDB-6

35

5

4

BDB-7

50

5

4

Mounting Method

In the following calibration scenarios, you can mount the calibration board on the last joint of the robot.

  • Automatic Calibration in the Eye to Hand (ETH) Scenario

  • Manual Calibration in the ETH Scenario (Multiple Random Calibration Board Poses)

For other calibration scenarios and intrinsic parameter checks, there is no need to mount the calibration board. Please place the calibration board in the center of the object plane.

Common ways to mount the calibration board are shown below:

Direct mounting Mounting through the flange adapter

mount calib board

mount flange