Capture Images from Line Scan Camera

You are currently viewing the documentation for the latest version (2.2.2). To access a different version, click the "Switch version" button located in the upper-right corner of the page.

■ If you are not sure which version of the product you are currently using, please feel free to contact Mech-Mind Technical Support.

Function

This Step obtains color images, depth maps, and point clouds from a real or virtual camera.

Usage Scenario

This Step is usually used as the starting input for a vision project. Data can be acquired using a line-scan structured-light camera or simulated using data from a virtual camera.

Input and Output

Input

This Step has no input ports.

Output

Output port Data type Description

Camera Depth Map

Image/Depth

Original depth map of the object.

Camera Color Image

Image/Color

Original color image of the object.

Point Cloud

PointCloud/XYZ

Object point cloud without normals.

Color Image Path

String

Path or file name of the color image read in virtual mode. The output content is determined by the Image Name Type parameter.

By default, the textured point cloud output by the "Capture Images from Line Scan Camera" Step is used as the scene point cloud in the project. If the default scene point cloud is used in the project, images will still be captured even when the "Capture Images from Line Scan Camera" Step is not connected to any subsequent Step.

Parameter Description

Parameter Description

Camera Type

Description: Specifies the camera type.

Virtual Mode

Description: When enabled, locally saved data is read through a virtual camera. When disabled, data is acquired from a connected real camera.

Default value: Disabled

The parameters for real and virtual modes are described below.

Use a Real Camera

Parameter Description

Camera ID

Description: Connects the camera and selects the calibration parameter group.

Instructions: Follow the steps below.

  1. Click Select camera to open the Choose the camera and calibration parameter group to use window.

  2. Select the camera you want to connect, and then click the "Connect" button icon 2. The camera is connected successfully when the "Connect" button icon 2 changes to the "Connected" status icon 3. Then click OK.

Camera Model

Description: This read-only parameter displays the model of the currently connected camera.

Calibration Parameter Group

Description: Specifies the calibration parameter group of the camera.

Default value: Null

Tuning recommendation: After the camera is successfully connected, the default calibration parameter group is automatically retrieved. When using the camera, ensure that the latest calibrated parameter group is applied to guarantee accurate reference frame transformation relationships in subsequent Steps.

If the current project has already completed camera calibration, and a new project is created while continuing to use the same camera, manually copy the calibration parameter group from the current project into the calibration folder of the new project. This enables the new project to reuse the same calibration parameter group without recalibration.

Configuration Parameter Group

Description: Selects the configuration parameter group of the camera. The camera acquires data according to the settings in this parameter group.

Default value: Null

Instructions: After the camera is successfully connected, the default parameter group is automatically retrieved. You can select the parameter group template corresponding to this camera model in the drop-down list.

Instructions: To adjust the camera parameters, click Adjust camera parameters. You can also manage parameter groups in Mech-Eye Viewer.

IP Address

Description: After the camera is successfully connected, the IP address is automatically retrieved. Do not change the IP address, as doing so will disconnect the camera.

Default value: Null

Timeout

Description: Sets the maximum time, in milliseconds (ms), from when the camera receives a message to when it returns data to the client. A timeout occurs in either of the following situations:

  • The camera fails to connect within the specified time.

  • The camera fails to acquire data within the specified time.

Disconnect

Description: Click Disconnect to disconnect the currently connected camera.

Data Acquisition Trigger Source

Description: Specifies the trigger source for camera data acquisition.

Max Capture Attempts

Description: Specifies the total number of data acquisition attempts when camera data acquisition fails due to a timeout.

Default value: 3

Recommended value: 3

Robot Name in Communication Configuration

Description: Specifies the robot name used in communication configuration. This name must match the name of the robot connected in communication configuration.

Default value: Null.

Use a Virtual Camera

Parameter Description

Configuration Parameter Group

Description: This parameter cannot be set in virtual mode.

Calibration Parameter Group

Instructions: After Data Path is selected, Calibration Parameter Group is automatically populated. If multiple calibration parameter groups exist under Data Path, select the desired camera calibration parameter group from the drop-down list.

Data Path

Description: Selects the folder containing the images and intrinsic and extrinsic camera parameters.

Playback Mode

Description: Specifies the order in which images are read.

Value list: Sequential, Repeat one, Repeat all, Random

  • Sequential: The default value. Reads images sequentially in the order they appear in the folder.

  • Repeat one: Reads the current image repeatedly.

  • Repeat all: Reads all images sequentially, then starts again from the first image after the last image has been read.

  • Random: Reads images in a random order.

Current Frame Name

Description: Displays the number or timestamp of the image currently being read.

Default value: Null

Image Name Type

Description: Selects the type of image name output by the Color Image Path port.

Value list: Complete Path, File Name, Base Name

Default value: Complete Path.

Max Capture Attempts

Description: Specifies the total number of attempts to acquire data.

Default value: 3

Is this page helpful?