Configure EtherNet/IP Communication in Mech-MSR

This section introduces how to configure the EtherNet/IP communication.

Configuration Process

Perform the following steps to configure EtherNet/IP communication:

  1. On the toolbar of Mech-MSR, click Communication Configuration.

  2. Click the ▶ icon on the left of EtherNet/IP to expand the settings.

  3. Set the Network Adapters and IP Address parameter. Take note that the PLC IP address and the IPC IP address must be on the same subnet.

  4. Click Open EDS folder to obtain the EDS file (Software EIP.eds) in the folder.

  5. Enable the communication.

eip config

If you want the EtherNet/IP communication service to be auto-enabled the next time you open the solution, you can select the Auto-enable the service check box.

The Auto-enable the service check box cannot be selected for both the EtherNet/IP and Adapter protocols.

General Parameter

Execution timeout period for return command

The maximum timeout period from the external device sending the return command to the external device receiving a valid response or triggering a timeout error. The default value is 10 seconds.


After you configure the communication in Mech-MSR, you can go to EtherNet/IP to learn the communication workflow.