Configure Siemens PLC Snap 7 Communication
This section introduces how to configure the Siemens programmable logic controller (PLC) Snap 7 communication. Before configuration, please confirm that you have already selected the robot and entered the Communication Option interface.
-
On the Communication Option interface, set the Set Interface Type parameter to Standard Interface, and set the Protocol parameter to Siemens PLC Client.
-
In the IP Address region, set the parameters as follows.
-
Specify the PLC IP Address parameter. The PLC IP address and the IPC IP address must be on the same subnet.
-
Specify the Slot number parameter. Refer to the following table for instructions.
-
Siemens S7 Series | Slot Number |
---|---|
S7-300 |
2 |
S7-1200 |
0 or 1 |
S7-1500 |
0 or 1 |
Other models |
0 |
-
Specify the DB number parameter.
-
(Optional) Select Auto enable interface service when opening solution. When the solution is opened, you do not need to start the interface service manually.
-
Click the Apply button.
-
Next, you need to complete the remaining standard interface configuration according to the used PLC.