Mech-Vision Project Unregistered (Error: 1001)

You are currently viewing the documentation for version 1.8.2. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

Symptom:

When triggering the Mech-Vision project to run using the Standard Interface, even if the “Autoload Solution” option has been checked for the project, the log displayed “Unregistered” or “Project is empty. Please make sure the autoload project is set”.

Affected Versions:

All versions.

Possible Causes:

  1. The "Procedure Out" Step was not added in the Mech-Vision project.

  2. Mech-Vision was in the Developer mode and the same project or solution was opened in multiple software.

  3. The communication component was interrupted, paused, or blocked due to an exception.

Solution:

  1. Add a "Procedure Out" Step in the Mech-Vision project.

  2. Go to Settings > Options in Mech-Vision, and disable the “Developer mode”.

  3. Open the Task Manager and check if the following program is running in the background. Right-click on it, then click End task and finally restart the software.