Convert Data Type

You are currently viewing the documentation for version 1.7.4. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

Function

You can customize the input/output port type of this Step, and the data type of the input port will be converted to the data type of the output port.

Usage Scenario

This Step is a general data conversion Step, with no fixed usage scenarios. It can be connected with other Steps according to actual data-type conversion requirements.

Input and Output

The input data type and the corresponding output data type(s) to which the input can be converted are listed in the table below. You can configure the ports of input data type and output data type according to the actual requirement.

Input Data Type Output Data Type

Pose2DList

StringList

BoolList

StringList, String, String

StringList

BoolList, String, NumberList

String

BoolList, StringList, NumberList

NumberList

BoolList, StringList, String, Variant, VariantList

LineSegmentList

StringList

Variant

BoolList, StringList, String, NumberList, VariantList

VariantList

BoolList, StringList, String, NumberList, Variant

Shape2DList

StringList

The figure below shows an example of converting NumberList to BoolList.

convert data type input and output

Parameter Description

  1. The Step does not have any input port or output port when it is just dragged to the graphical programming workspace, as shown below.

    convert data type initial state
  2. Go to the Step Parameters panel, select the input data type and output data type in the drop-down lists, and then corresponding ports will be added to the Step.

    convert data type select data type
  3. Connect Steps.

    An example of possible connection is shown below.

    convert data type connection step

    You should pay attention to the dependency relationship between input port and output port while using this Step:

    • When you change the data type of either the input or the output port, if the new data type cannot be converted to/from the data type of the other port, the data type of this other port is reset.

    • If the data type of a port is changed (including the reset mentioned above), connection(s) to this port is deleted, and you will need to reconnect the Steps.

We Value Your Privacy

We use cookies to provide you with the best possible experience on our website. By continuing to use the site, you acknowledge that you agree to the use of cookies. If you decline, a single cookie will be used to ensure you're not tracked or remembered when you visit this website.