Too Dark 2D Images Captured by LSR L-GL/LSR S-GL/DEEP-GL V4 during Calibration

You are currently viewing the documentation for the latest version (2.1.0). To access a different version, click the "Switch version" button located in the upper-right corner of the page.

■ If you are not sure which version of the product you are currently using, please feel free to contact Mech-Mind Technical Support.

Symptom:

In the hand-eye calibration with LSR L-GL/LSR S-GL/DEEP-GL V4 cameras, the 2D images captured by the cameras were too dark.

Affected Software Versions:

Mech-Vision 1.6.1 and later versions

Possible Cause:

The LSR/DEEP-GL series consist of a 2D camera (texture) and two 2D cameras (depth source). For 2D images captured by 2D monochrome cameras in Hand-eye calibration, you should increase the value of the 2D Image (Depth Source) Exposure Time parameter in Mech-Eye Viewer if the environment is relatively dark.

Solution:

Follow these steps to fix the issue:

  1. Connect to the LSR L-GL/LSR S-GL/DEEP-GL V4 camera through Mech-Eye Viewer.

  2. Select “calib” under Parameter group.

  3. Increase the 2D Image (Depth Source) Exposure Time or set Increase the 2D Image (Depth Source) Exposure Time to Flash and re-calibrate the camera.

  4. Add light to the environment if the issue persists.

We Value Your Privacy

We use cookies to provide you with the best possible experience on our website. By continuing to use the site, you acknowledge that you agree to the use of cookies. If you decline, a single cookie will be used to ensure you're not tracked or remembered when you visit this website.