Classify

Function

This Step is used before or after Vision Move to choose different branches according to the workobject labels identified by Mech-Vision.

Usage Scenario

This Step is used to classify the workobject labels identified by Mech-Vision.

  • Before “Vision Move”: The default picking process: Identify the workobject > Select and operate on different branches according object’s labels > Pick workobjects with the label. Example: Change the gripper for different workobjects.

  • After “Vision Move”: The default picking process: Identify the object > Pick the object > Operate differently according to the types of workobjects. Example: Use the same gripper to pick and place workobjects into different bins after classification.

Parameter Description

General Parameters of Non-Move Steps

Skip Execution
None

Default setting. Do not skip the current Step.

Simulation only

Skip the current Step during simulation. The exit port is specified by Out Port When Skip.

Always

Skip the current Step when the project is simulating or running. The exit port is specified by Out Port When Skip.

Instruction

When Simulation only or Always is selected, the current Step will be skipped and the subsequent Step will be executed when running the project. If this parameter is set to None in “Check DI” Step in the project, and there is no external input signal during simulation, the project will be stopped when executing to this Step. In this case, setting the parameter to Simulation only or Always enables the simulation to continue.

Out Port When Skip

This parameter will take effect when Skip Execution is set to Simulation only or Always. It specifies the exit port when skipping a Step.

Get Label from “Update Held Workobject”

Selected

An Update Held Workobject Step should be used before this Step, and this Step can acquire the label information of the currently picked workobject and then perform operations according to the classification. Usage Scenario: The label information of the detected workobjects cannot be acquired directly due to the overlapped workpieces or other reasons; therefore, the held workpieces should be re-classified, and then corresponding labels can be output.

Unselected

The default setting. Use the object labels detected by Mech-Vision. Please select the corresponding Vision Move Step for Classify before “Vision Move”.

Load Labels & Add a label

upload add label
Load Labels

Add multiple labels to Unused Labels at once. Click Load Labels and select a JSON file with multiple labels, as shown below. After that, all label files will be added to Unused Labels, and all the previous labels in both the Unused Labels and the Used Labels will be deleted.

label file
Add a label

Add a label named unnamed_label to Unused Labels. You can double-click the label to re-name it.

Label list

The label list includes Unused Labels and the Used Labels. You can shift the label’s place between the two spaces by clicking icon_right or icon_left.

The Used Labels will appear at the exit port of this Step. There will be a label named Other to filter out labels that are not in the Used Labels space.