ABB RobotWare 7 Automatic Calibration

You are currently viewing the documentation for the latest version (2.1.0). To access a different version, click the "Switch version" button located in the upper-right corner of the page.

■ If you are not sure which version of the product you are currently using, please feel free to contact Mech-Mind Technical Support.

This topic introduces the process of automatic calibration via Standard Interface communication between the ABB RobotWare 7 robot and Mech-Mind Vision System.

Preparation before Calibration

Make preparation before calibration according to the camera mounting method.

Pre-calibration Configuration

  1. Open Mech-Vision, and click the Camera Calibration button in the toolbar. The Configuration before Calibration window will be prompted.

  2. Confirm that the checks are performed, click I’ve finished all checks, and then click Next.

  3. In the Select how to calibrate window, select the New calibration radio button, and then click the Next button.

  4. In the Select calibration task window, select Hand-eye calibration for listed robot from the drop-down list box, click the Select robot model button to select the robot model used by the project, and then click the Next button.

  5. In the Select camera setup window, select the camera mounting method in this project, and then click the Next button.

  6. In the Calibration method and robot control window, select Automatic and Standard Interface, and then click the Calibrate button to go to the Calibration window.

Calibration Procedure

Conduct calibration according to the camera mounting method.

Precautions

  • When you proceed to the third calibration step (connecting the robot) and you click Start interface service button in the Connect the robot window, the button will change to Waiting for the robot to connect.... If the interface service is already started, you do not need to perform this operation.

  • When the button displays Waiting for the robot to connect..., perform the following steps on the robot side. Then, continue the calibration in the software.

1. Select and Modify Calibration Program

In manual mode, select Home  Code  Tasks  T_ROB1, and then open the MM_Auto_Calib module in T_ROB1. Ensure that the IP address in the MM_Init_Socket line in the program module is the IP address of the IPC, and the port is the same as the setting in Mech-Vision. For detailed instructions on the operation, see Select and Modify the Program Used for the Communication Test.

calilbration process1
calilbration process2

2. Teach Calibration Start Point

  1. In manual mode, move the robot to the calibration start point.

  2. Select the following code. Then, click Update Position in the left menu. In the pop-up window, click Update to save the current pose of the robot to p0.

    calilbration process3
    calilbration process4
  3. If there is a 7th axis which is controlled by the robot on site, modify “IsAxis7:=0;” to “IsAxis7:=1;” and modify the value of Axis7 accordingly (Axis7:=XX, XX refers to the current value of the 7th axis). If there is not a 7th axis, or the 7th axis is controlled by a PLC, you may skip this step.

    calilbration process5

3. Run Calibration Program

  1. In the manual mode, select Debug  PP to Routine in the right-side interface of the program MM_Auto_Calib.

    calilbration process6
  2. After selecting MM_Calibration, select OK.

    calilbration process7
  3. Select icon controlpanel, open Control, and then switch to the Auto mode (ensure that the auto mode is enabled in the pop-up window). Then, turn the motors on and reduce the velocity.

    calilbration process8
  4. Press the start key when the interface displays the content below. When, in the Configuration window in Mech-Vision, the current status changes to connected and the button Waiting for the robot to connect changes to Disconnect robot, click Next. Next, proceed to the fourth step of the calibration process (i.e. setting the movement path).

    calilbration process9
    start calilbration1

Change the Extrinsic Parameter File

If the camera’s extrinsic parameter file has been used by a Mech-Vision project, you need to change the extrinsic parameter file used by the Mech-Vision project to a new one after you finish the hand-eye calibration.

  1. Select the Capture Images from Camera Step.

    change calibration parameter group
  2. In the Step Parameters panel, click change calibration parameter group icon of the Calibration Parameter Group parameter, and select the newly calibrated extrinsic parameter file.

Calibration-Related Status Codes

During automatic calibration via Standard Interface communication, the vision system returns data together with the status code to the robot. Status codes, which are categorized into error codes and normal status codes, indicate the command execution status. Calibration related status codes are listed in the tables below.

Error codes

Error code Description

Calibration: Parameter error

Calibration: No calibration flange pose provided from Mech-Vision

Calibration: No calibration joint angles provided from Mech-Vision

Calibration: Robot failed to reach calibration point

Normal status codes

Normal status code Description

7100

Calibration: Robot moved to the calibration point successfully

7101

Calibration: Pose received from Mech-Vision successfully