Calc Parallelism Error

You are currently viewing the documentation for version 1.8.1. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

This Step is used to calculate the parallelism error from the target planar point cloud to the reference planar point cloud.

  • Parallelism is defined as the quality or condition of two planes/edges being parallel, which is measured by the maximum allowable error between one plane/edge and the other. It evaluates whether the lines, planes, or the line and the plane are parallel.

  • Parallelism error is the difference between the measured plane/edge and the reference plane/edge.

Before using this Step, please refer to Getting Started with Measurement Mode to learn about basics of Measurement Mode.

Application Examples

calc parallelism error application sample

Connect Steps

Click Calc Parallelism Error, go to the Step Input Source Selection panel, and then

  • select Read Point Cloud V2_1_Point Cloud With Normals as Input 1 (Target Planar Point Cloud) and

  • select Read Point Cloud V2_2_Point Cloud With Normals as Input 2 (Reference Planar Point Cloud).

Configure parameters

Click the Step and configure the Point Cloud Source (target cloud) and other parameters in the Step Parameters panel.

Click the Step and configure the Point Cloud Source (reference point cloud) and other parameters in the Step Parameters panel.

The point clouds used in this sample application are shown below (target cloud on the left and reference point cloud on the right).

calc parallelism error point cloud sample

Click Run to run the project after the settings.

Read the result

After running the project, click Calc Flatness Error and check the parallelism error in the Measurement Output panel.

calc parallelism error measure result

You can set the LSL (lower specification limit) and USL (upper specification limit) in the Measurement Output and Result View panels to check whether the measurement conforms to the specification.