FANUC Error Messages
The following errors may occur while running the Standard Interface program on the robot.
Robot Internal Error
MM: Robot_Internal_Error
-
Cause: Error occurred while the robot program attempts to call the system function.
-
Troubleshooting: Please examine the program by referring to FANUC robot programming manual.
Communication Connection Error
MM: Robot_Socket_Closed
-
Cause: Error occurred when the robot program called the MSG_CONNECT procedure to establish communication.
-
Troubleshooting:
-
Check if the hardware is properly connected.
-
Check if the Standard Interface service (TCP HEX) is started in Mech-Vision.
-
Check the IP addresses of the robot and the IPC, and if the port number is configured correctly.
-
Check if the firewall is turned off on the IPC.
-
Please contact Mech-Mind Technical Support for further assistance.
-
Procedure Argument Error
MM: Robot_Argument_Error
-
Cause: When calling a Mech-Mind Standard Interface procedure, arguments provided are not correct.
-
Troubleshooting: Please refer to FANUC Standard Interface Commands and input the correct arguments accordingly.
Interface Command Error
MM: Robot_CMD_Error
-
Cause: The command code returned to the robot does not match the one sent to Mech-Vision.
-
Troubleshooting: The sequence of command sending and receiving is problematic. Please contact Mech-Mind Technical Support for further assistance.
Status Code Error
MM: IPC_Return_Error
-
Cause: Returned status code is an error code. Please check the messages in the Console tab of Mech-Vision Log panel.
-
Troubleshooting:
-
Please refer to the Status Codes and Troubleshooting for the specific error.
-