When Running the Main Control Program on the FANUC Robot, the System Reported a Task Execution Failure (SYST-011) and Indicated That the UOP Was Acting as the Master Control Device (SYST-005)

You are currently viewing the documentation for a pre-release version (2.2.0). To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

Problem

When running the main control program on the FANUC robot, the system reported a task execution failure (SYST-011) and indicated that the UOP was acting as the master control device (SYST-005).

Possible Causes

This error will be triggered if the start button on the robot controller is used to start the robot while it is in remote mode.

Solutions

Set Remote/Local setup to Local. Then, restart the robot by using the start button on the controller.

faq1 1