Camera Indicator Lights Indicated Abnormality after Power Was Connected

After the camera is connected to power, you can check the indicator lights on the camera to see if its in proper working condition.

This topic provides the troubleshooting guidance for three issues that can be discovered through the indicator lights.

  • This topic is applicable for V4 cameras. If you encounter similar issues with V3 cameras, please contact Technical Support.

  • For the display of the indicator lights in working condition, please refer to Camera Hardware User Manual.

All Indicator Lights Off

Symptom

After the camera was connected to power, none of the four indicator lights on the camera were lit.

Possible Causes

  • The camera cables are not connected correctly.

  • The voltage of the power supply is abnormal.

  • The DIN rail power supply is not grounded.

Solution

Please follow these steps to troubleshoot the issue:

  1. Refer to Camera Hardware User Manual and check if the camera cables are correctly connected and the connector nuts are fully tightened.

    • If the camera cables are not correctly connected, please correct the connection and check indicator lights on the camera again.

      • If the indicator lights on the camera indicate proper working condition, the troubleshooting is completed.

      • If the indicator lights still indicate the presence of issues, proceed to step 2.

    • If the camera cables are correctly connected, proceed to step 2.

  2. Disconnect the camera DC power cable from the camera, and use a multimeter to check the voltage of the M-12 A connector and see if it reaches 24 V.

    • If the voltage does not reach 24 V, check aspects such as the connection of other cables in the power supply line and make corresponding corrections. Then, connect the DC power cable to the camera again and check the indicator lights on the camera.

      • If the indicator lights on the camera indicate proper working condition, the troubleshooting is completed.

      • If the indicator lights still indicate the presence of issues, proceed to step 3.

    • If the voltage reaches 24 V, proceed to step 3.

  3. Check if the power supply is correctly grounded: if a DIN rail power supply is used to supply power to the camera, refer to Camera Hardware User Manual to check if the PE wire of the DIN rail power supply is correctly connected. If a power adaptor is used to supply power to the camera, check if the power outlet to which the 3-prong connector of the adaptor AC power cable is connected is correctly grounded.

    • If the power supply is not correctly grounded, the camera might have been damaged. Please contact Technical Support.

    • If the power supply is correctly grounded but the symptom is still present, please contact Technical Support.

PWR Indicator Light Solid Red

Symptom

After the camera was connected to power, the PWR indicator light was solid red.

Possible Causes

The voltage of the power supply is abnormal.

Solution

Please follow these steps to troubleshoot the issue:

  1. Refer to Camera Hardware User Manual and check if the camera DC power cable is correctly connected and the connector nut is fully tightened.

    • If the camera DC power cable is not correctly connected, please correct the connection and check indicator lights on the camera again.

      • If the indicator lights on the camera indicate proper working condition, the troubleshooting is completed.

      • If the indicator lights still indicate the presence of issues, proceed to step 2.

    • If the camera DC power cable is correctly connected, proceed to step 2.

  2. Disconnect the camera DC power cable from the camera, and use a multimeter to check the voltage of the M-12 A connector and see if it reaches 24 V.

    • If the voltage does not reach 24 V, check aspects such as the connection of other cables in the power supply line and make corresponding corrections. Then, connect the camera DC power cable to the camera again and check the indicator lights on the camera.

      • If the indicator lights on the camera indicate proper working condition, the troubleshooting is completed.

      • If the indicator lights still indicate the presence of issues, please contact Technical Support.

Symptom

After the camera was connected to power, , the PWR indicator light was solid green, but the LINK indicator light was not lit.

Possible Causes

The network connection is abnormal.

Solution

Please follow these steps to troubleshoot the issue:

  1. Refer to Camera Hardware User Manual and check if the camera Ethernet cable is correctly connected and the connector nut is fully tightened.

    • If the camera Ethernet cable is not correctly connected, please correct the connection and check indicator lights on the camera again.

      • If the indicator lights on the camera indicate proper working condition, the troubleshooting is completed.

      • If the indicator lights still indicate the presence of issues, proceed to step 2.

    • If the camera Ethernet cable is correctly connected, proceed to step 2.

  2. Replace the camera Ethernet cable, and then check the indicator lights on the camera again.

    • If the indicator lights on the camera indicate proper working condition, the troubleshooting is completed.

    • If the indicator lights still indicate the presence of issues, please contact Technical Support.

The following issues might be caused by the same reasons. If you also encountered these issues, after resolving the issue in this topic, you can check if these other issues have been resolved as well.

We Value Your Privacy

We use cookies to provide you with the best possible experience on our website. By continuing to use the site, you acknowledge that you agree to the use of cookies. If you decline, a single cookie will be used to ensure you're not tracked or remembered when you visit this website.