LSR S
Physical Specifications
Model |
LSR S |
---|---|
Dimensions(1) |
228 × 77 × 126 mm |
Weight(1) |
1.9 kg |
Baseline |
140 mm |
Light source |
Red laser (638 nm, Class 2) |
Operating temperature |
-10–45°C |
Operating humidity |
0–85%RH, non-condensing |
Storage temperature |
-20–60°C |
Communication interface |
Gigabit Ethernet |
Input |
24 VDC, 3.75 A |
Power |
Idle: 22 W Average: 30 W Peak: 60 W |
IP rating(2) |
IP67 |
Cooling |
Passive |
Flatness tolerance for mounting surface(3) |
± 0.05 mm |
Vibration tolerance(4) |
Sinusoidal vibration along the X-, Y-, and Z-axes, 10–57 Hz, 1.5 mm peak-to-peak value, 3 hours per axis |
Shock tolerance(5) |
Half sine shock pulses along the positive and negative directions of the X-, Y-, and Z-axes, 147 m/s2 (15 g), 11 ms, 3 shocks per direction, 18 shocks in total |
(1) Heat-dissipation panel not included.
(2) Test implemented based on IEC 60529. 6: dust-tight; 7: protected against the effects of temporary immersion in water.
(3) The flatness of the surface used to mount the camera should satisfy this requirement.
(4) Test implemented based on IEC 60068-2-6.
(5) Test implemented based on IEC 60068-2-27.
Performance Specifications
Working distance |
500–900 mm |
900–1500 mm |
---|---|---|
Recommended working distance |
500–900 mm |
900–1500 mm |
Object focal distance(1) |
800 mm |
1400 mm |
FOV (near) |
480 × 360 mm @ 0.5 m |
|
FOV (far) |
1500 × 1200 mm @ 1.5 m |
|
Depth map resolution |
2048 × 1536 |
|
RGB image resolution(2),(3) |
4000 × 3000 |
|
Typical capture time(4),(5) |
0.5–0.9 s |
|
Recommended warm-up time(4),(6) |
60 min |
|
Point Z-value repeatability (1σ)(4),(7) |
0.2 mm @ 1.5 m |
|
Measurement accuracy (VDI/VDE)(4),(8) |
1.0 mm @ 1.5 m |
(1) The object focal distance of the 2D camera inside the product.
(2) Can be changed to 2000 × 1500 through Mech-Eye Viewer.
(3) RGB image refers to the 2D image (texture) in Mech-Eye Viewer.
(4) Unless otherwise specified, this test was conducted under the standard test conditions.
(5) The range of time taken to acquire data using Mech-Eye Viewer in the Fast and Accurate fringe coding mode.
(6) The recommended warm-up time required to guarantee data accuracy to the listed values. For the warm-up method, refer to the user manual (The data acquisition interval is 10 s). Please adjust the warm-up time based on the actual data acquisition interval, ambient temperature, and heat-dissipation conditions.
(7) The standard deviation of the 100 measured depth values of each point on the target object was calculated, and then the median of all the standard deviations was taken. The target object was a white ceramic plate with a rough surface. The Point Cloud Processing parameters were set to Off.
(8) Test implemented with reference to VDI/VDE 2634 Part 2.
Certifications
Safety of Laser Products
The laser classification is implemented based on IEC 60825-1:2014 in accordance with the requirements of Laser Notice No. 56 of the FDA (CDRH).
Model |
Wavelength |
Max. output power |
Laser class |
---|---|---|---|
LSR S |
638 nm |
2.46 mW |
Class 2 |
CE
Hereby [Mech-Mind Robotics Technologies Ltd.] declares that [LSR S] is in compliance with the Electromagnetic Compatibility Directive 2014/30/EU.
The full text of the EU Declaration of Conformity is available at https://downloads.mech-mind.com/?tab=tab-eu-dec
Standard Test Conditions
Working distance(1) |
500–900 mm |
900–1500 mm |
||
---|---|---|---|---|
Ambient temperature |
15–30°C |
|||
Ambient humidity |
0–85%RH, non-condensing |
|||
Ambient light intensity |
200–1000 lx |
|||
Camera parameters(2) |
8 ms |
|||
Timed (Exposure Time: 50 ms) |
||||
Flash (Flash Acquisition Mode: Fast) |
||||
0 dB |
||||
100% |
||||
Accurate |
||||
Normal |
||||
Normal |
||||
Normal |
||||
Tested region(3) |
Length: 90% of FOV length Width: 90% of FOV width Position: center of FOV |
|||
RGB image resolution |
4000 × 3000 |
(1) For the object focal distance of 800 mm, the working distance used in tests is 500–900 mm. For the object focal distance of 1400 mm, the working distance used in tests is 900–1500 mm.
(2) Parameters not listed are set to their default values.
(3) Test data was obtained from this region.