NANO
Physical Specifications
Model |
NANO |
|
---|---|---|
Dimensions |
145 × 51 × 85 mm |
|
Weight |
0.7 kg |
|
Baseline |
68 mm |
|
Light source |
Blue LED (459 nm, RG2) |
White LED (RG2) |
2D image color |
Monochrome |
Color |
Operating temperature |
0–45°C |
|
Operating humidity |
0–85%RH, non-condensing |
|
Storage temperature |
-20–60°C |
|
Communication interface |
Gigabit Ethernet |
|
Input |
24 VDC, 1.5 A |
|
Power |
Idle: 8 W Average: 14 W Peak: 24 W |
|
IP rating(1) |
IP65 |
|
Cooling |
Passive |
|
Flatness tolerance for mounting surface(2) |
± 0.05 mm |
|
Vibration tolerance(3) |
Sinusoidal vibration along the X-, Y-, and Z-axes, 10–57 Hz, 1.5 mm peak-to-peak value, 3 hours per axis |
|
Shock tolerance(4) |
Half sine shock pulses along the positive and negative directions of the X-, Y-, and Z-axes, 147 m/s2 (15 g), 11 ms, 3 shocks per direction, 18 shocks in total |
(1) Test implemented based on IEC 60529. 6: dust-tight; 5: protected against water jets.
(2) The flatness of the surface used to mount the camera should satisfy this requirement.
(3) Test implemented based on IEC 60068-2-6.
(4) Test implemented based on IEC 60068-2-27.
Performance Specifications
Working distance |
300–450 mm |
450–600 mm |
---|---|---|
Recommended working distance |
300–450 mm |
450–600 mm |
Object focal distance(1) |
350 mm |
550 mm |
FOV (near) |
220 × 150 mm @ 0.3 m |
|
FOV (far) |
440 × 300 mm @ 0.6 m |
|
Resolutions |
1280 × 1024 |
|
Typical capture time(2),(3) |
0.6–1.1 s |
|
Recommended warm-up time(2),(4) |
30 min |
|
Point Z-value repeatability (1σ)(2),(5) |
0.1 mm @ 0.5 m |
|
Measurement accuracy (VDI/VDE)(2),(6) |
0.1 mm @ 0.5 m |
(1) The object focal distance of the 2D camera inside the product.
(2) Unless otherwise specified, this test was conducted under the standard test conditions.
(3) The range of time taken to acquire data using Mech-Eye Viewer in the Fast and Accurate fringe coding mode.
(4) The recommended warm-up time required to guarantee data accuracy to the listed values. For the warm-up method, refer to the user manual (The data acquisition interval is 10 s). Please adjust the warm-up time based on the actual data acquisition interval, ambient temperature, and heat-dissipation conditions.
(5) The standard deviation of the 100 measured depth values of each point on the target object was calculated, and then the median of all the standard deviations was taken. The target object was a white ceramic plate with a rough surface. The Point Cloud Processing parameters were set to Off.
(6) Test implemented with reference to VDI/VDE 2634 Part 2.
Certifications
CE
Hereby [Mech-Mind Robotics Technologies Ltd.] declares that [NANO] is in compliance with the Electromagnetic Compatibility Directive 2014/30/EU.
The full text of the EU Declaration of Conformity is available at https://downloads.mech-mind.com/?tab=tab-eu-dec
Standard Test Conditions
Working distance(1) |
300–450 mm |
450–600 mm |
||
---|---|---|---|---|
Ambient temperature |
15–30°C |
|||
Ambient humidity |
0–85%RH, non-condensing |
|||
Ambient light intensity |
200–1000 lx |
|||
Camera parameters(2) |
5 ms |
|||
Timed (Exposure Time: 80 ms) |
||||
0 dB |
||||
High |
||||
Accurate |
||||
Normal |
||||
Normal |
||||
Normal |
||||
Tested region(3) |
Length: 90% of FOV length Width: 90% of FOV width Position: center of FOV |
(1) For the object focal distance of 350 mm, the working distance used in tests is 300–450 mm. For the object focal distance of 550 mm, the working distance used in tests is 450–600 mm.
(2) Parameters not listed are set to their default values.
(3) Test data was obtained from this region.