Acquire and View Data

Once the laser profiler is successfully connected, the following interface is displayed. In this interface, you can switch the data acquisition mode, acquire data, and view the data.

acquisition
  1. Switch Data Acquisition Mode

  2. Acquire Data

  3. Switch Data Type

Switch Data Acquisition Mode

Click the corresponding button to switch the data acquisition mode:

  • Profile mode: used to acquire the raw image and profile, and adjust the relevant parameters.

  • Scan mode: used to acquire the intensity image, depth map, and point cloud, and adjust the relevant parameters.

Read Scanning Mechanism of Laser Profiler to familiarize yourself with the scanning mechanism of the laser profiler.

Acquire Data

You can acquire data with the single cap and continuous cap buttons in the data acquisition area. The functions of these buttons differ in different data acquisition modes.

Profile Mode

In the profile mode, click the above buttons to acquire the raw image and profile.

  • single cap: Click this button to acquire one raw image and one profile.

  • continuous cap Click this button to start acquiring raw images and profiles continuously at the predetermined interval. After the acquisition has started, this button changes to stop cap. Click it again to stop the continuous acquisition.

Scan Mode

In the scan mode, the functions of the above buttons differ according to the method of triggering data acquisition in use.

Read Methods for Triggering Data Acquisition and Workflow of Triggering Data Acquisition to familiarize yourself with the different methods of triggering the laser profiler to acquire data.
  • External:

    • single cap: This button is not available.

    • continuous cap: Enter the laser profiler into the acquisition ready status. The laser profiler can only respond to externally input signals after it enters the acquisition ready status.

  • Software:

    • single cap: Enter the laser profiler into the acquisition ready status and start one round of data acquisition. After the acquisition has started, this button changes to stop single cap. Click it again to stop the current round of data acquisition.

    • continuous cap: Enter the laser profiler into the acquisition ready status and start rounds of data acquisition continuously. After the acquisition has started, this button changes to stop cap. Click it again to stop the continuous acquisition.

Switch Data Type

The laser profiler outputs multiple types of data to Mech-Eye Viewer. Click the data type buttons to view the corresponding type of data.

Data Types in Profile Mode

In the profile mode, you can view the Raw Image and Profile types of data.

Data type Description Example

Raw image

Used to check the brightness and location of the laser lines.

raw image

Profile

Used to check the profile extraction result, such as the amount of gaps in the profile.

profile screenshot

On the profile, the depth value of the extraction spot in the column of pixels where the cursor is located is displayed.
Explanation of the raw image

In a raw image:

  • The white part represents the laser line reflected by the target object’s surface.

  • The line composed of the blue dots is the extracted profile. Each blue dot is a spot, which is the data point extracted from each column of pixels in the raw image.

For the process of extracting a profile, refer to Profile Extraction Process.

raw image explained

Data Types in Scan Mode

In the scan mode, you can view the Intensity Image, Depth Map, and Point Cloud types of data.

Data type Description Example

Intensity image

A 2D image that represents the reflectivity of the object surface

intensity image

Depth map

A 2D image that contains the depth information of the object surface

depth map

Point cloud

A collection of data points that represent the 3D shape of the object surface

point cloud

Adjust Data Display

In the data display area, you can adjust the display of the data through mouse actions, keyboard, and buttons and menus in the software interface.

Adjust Raw Image Display

In the raw image display, you can perform the following actions:

  • Zoom: While the cursor is on the raw image, scroll the mouse wheel to zoom the raw image.

  • Move: While the raw image is zoomed in, hold and drag to move the raw image.

  • Reset size: Right-click the raw image and select Reset View to fit it to the window.

  • Check grayscale values: In the image information box at the lower right of the raw image, you can check the grayscale value of the pixel where the cursor is located.

    To hide the image information box, uncheck Image Information Box in the View menu.

  • Display the exposure information: Display pixels with different grayscale values in different colors to help adjust parameters. For details, refer to Exposure Information, Intensity Curve, and Sharpness Curve.

  • Display the intensity and sharpness curves: Display the intensity and sharpness curves of the profile to help adjust parameters. For details, refer to Exposure Information, Intensity Curve, and Sharpness Curve.

    When you zoom and move the raw image, the intensity and sharpness curves zoom and move together. You can also zoom and move the intensity and sharpness curves, and the raw image will zoom and move together.

Adjust Profile Display

In the profile display, you can perform the following actions:

  • Check the coordinates of extraction spots: While the cursor is in the profile reference frame grid, the coordinates of the extraction spot of the column of pixels where the cursor is located is displayed in real time.

  • Zoom: While the cursor is in the profile reference frame grid, scroll the mouse wheel to zoom the profile.

  • Move: While the profile is zoomed in, hold and drag to move the profile.

  • Reset size: Right-click the profile and select Reset View to fit it to the window.

Adjust Intensity Image Display

In the intensity image display, you can perform the following actions:

  • Zoom: While the cursor is on the intensity image, scroll the mouse wheel to zoom the intensity image.

  • Move: While the intensity image is zoomed in, hold and drag to move the intensity image.

  • Reset size: Right-click the intensity image and select Reset View to fit it to the window.

  • Check pixel position and grayscale values: In the image information box at the lower right of the intensity image, you can check the pixel position and grayscale values of the pixel where the cursor is located.

    • The pixel position of the upper-left corner of the image is (0, 0).

    • To hide the image information box, uncheck Image Information Box in the View menu.

Adjust Depth Map Display

In the depth map display, you can perform the following actions:

  • Zoom: While the cursor is on the depth map, scroll the mouse wheel to zoom the depth map.

  • Move: While the depth map is zoomed in, hold and drag to move the depth map.

  • Reset size: Right-click the depth map and select Reset View to fit it to the window.

  • Check pixel position and coordinates: In the image information box at the lower right of the depth map, you can check the pixel position and coordinates (in mm) in the laser profiler reference frame of the pixel where the cursor is located.

    • The pixel position of the upper-left corner of the image is (0, 0).

    • To hide the image information box, uncheck Image Information Box in the View menu.

  • Adjust depth data display: The display of the depth data can be adjusted in the left panel. For detailed instructions, please refer to Adjust Depth Data Display.

Adjust Point Cloud Display

In the point cloud display, you can perform the following actions:

  • Zoom: While the cursor is on the point cloud, scroll the mouse wheel to zoom the point cloud.

  • Rotate: Hold the left mouse button and drag to rotate the point cloud.

  • Pan: Hold the mouse wheel and drag to pan the point cloud.

  • Adjust depth data display: The display of the depth data can be adjusted in the left panel. For detailed instructions, please refer to Adjust Depth Data Display.

  • Use the icons in the upper right corner of the data display area to adjust the display of the point cloud and reference frame:

    Icon Feature

    icon frame

    Hold and drag the icon to rotate the view. Click one of the circles to rotate the view so that the coordinate axis on the custom reference frame represented by the circle points forward.
    For example, click the -X circle to rotate the view so that the negative direction of the X-axis of the custom reference frame points forward.

    icon drag

    Hold and drag the icon to pan the view.

    icon zoom

    Hold and drag the icon to zoom the point cloud.

    icon fit

    Click the icon to adjust the point cloud and reference frame to fit the window size.

    icon view

    Click the icon to switch between the perspective and orthographic view for the point cloud.

    icon key

    After clicking the icon, the window prompts the key or mouse button that you press. Click the icon again to stop the prompts.

    icon grid

    Click the icon to display the reference frame grid. Click the icon again to hide the grid.

Adjust Depth Data Display

In the left panel of the depth map or point cloud display, you can adjust the display reference frame, color rendering, and range of the depth data.

Change Reference Frame

In the Reference Frame menu at the top of the left panel, you can select the reference frame used for displaying the depth data.

The reference frame setting is simultaneously applied to both depth map and point cloud.

Change Color Rendering

In the Color menu in the left panel, you can choose the color rendering scheme of the depth data.

The Jet, Grayscale, and Jet + intensity options are available for both the depth map and point cloud. When one of these three options is selected, the depth range of the color rendering can be adjusted.

Option Description Example

Jet

Depth values are displayed in different colors of the jet color scheme.

point cloud jet

Grayscale

Depth values are displayed in different shades of gray.

point cloud grey

Jet + intensity

The intensity information of the object surface is overlaid on the jet color scheme. Suitable for checking the object surface features and depth changes at the same time.

point cloud jet intensity

The Untextured and Textured options are only available for the point cloud.

Option Description Example

Untextured

Displays the untextured, white point cloud.

point cloud white

Textured

Display the point cloud textured with the intensity image.

point cloud 2d

When Untextured or Textured is selected, if you switch to the depth map display and then switch back to the point cloud display, the Color setting will be automatically changed to the option selected in the depth map display.

Adjust Depth Range of Color Rendering

When the depth map and point cloud are displayed in Jet ,Grayscale or Jet + intensity, every time data acquisition is performed, Mech-Eye Viewer automatically adjusts the color rendering according to the range of the obtained depth data.

With the functions in the Range section of the left panel, you can adjust the depth range in which the color is rendered, in order to conveniently observe the depth variation in a specific range.

The depth range of color rendering is simultaneously applied to both depth map and point cloud.

Follow these steps to adjust the color rendering range of the depth data:

  1. Adjust the range of depth data to be displayed: adjust the Min and Max values at the two ends of the slider. Depth data outside this range is not displayed.

  2. Check the rough depth: On the depth map, move the cursor to the area to be observed, and check the third value of Coordinates in the image information box in the lower right. This is the depth value.

  3. Adjust depth range of color rendering: Move the slider handles or enter the depth values on the right of the slider to adjust the depth range of color rendering according to your needs.

    After adjusting the range, the depth values outside this range are displayed in the colors corresponding to the minimum/maximum depth values.

  4. Lock the range: If you need to compare the depth variations in the same range across multiple acquisitions, you can check the Lock option above the slider. When you acquire data again, the depth range of color rendering manually adjusted will be used.

To change back to the automatically adjusted range, uncheck Lock and click Reset to the upper right.

This topic introduced data acquisition and data types. The next topic will introduce actions related to parameters.

We Value Your Privacy

We use cookies to provide you with the best possible experience on our website. By continuing to use the site, you acknowledge that you agree to the use of cookies. If you decline, a single cookie will be used to ensure you're not tracked or remembered when you visit this website.