Manual Re-Calibration in the Eye-in-Hand Setup (Four-Axis Robots - Using Multiple Random Calibration Board Poses Method)
This how-to guide introduces how to complete the manual calibration for four-axis robots using the multiple random calibration board poses method in the eye-in-hand (EIH) setup.
Preparation before Calibration
Prepare the Materials Required for Calibration
Before hand-eye re-calibration, you need to finish the following preparations:
-
Locate the calibration board provided with the project. Ensure that the circles of the calibration board are clearly visible and without obvious scratches, and the board does not suffer from deformations.
-
Please place the calibration board in the center of the working plane, where target objects are to be placed.
-
Move the robot to the start position for calibration.
For the pose of the calibration start position, please refer to the pose recorded during the project deployment phase.
Adjust the Effect of Calibration Board’s Point Cloud
-
Open Mech-Eye Viewer to adjust camera parameters.
-
Adjust the 2D parameters to make sure that the 2D image of the calibration board is clear and neither overexposed nor underexposed.
-
Adjust 3D parameters to make sure that the point clouds of the circles on the calibration board are complete and have clear contours. It is recommended to set Surface Smoothing and Outlier Removal to Normal in the Point Cloud Processing section to reduce the point cloud fluctuation range.
If the on-site ambient lights are not ideal and affect the quality of 2D images and point clouds, you can use shading or supplemental light to improve the lighting conditions.
-
Make sure that the images and point cloud of the calibration board are up to standard after completing the preceding steps.
Normal Overexposed Underexposed 2D image
Point cloud
Pre-calibration Configuration
-
Open Mech-Vision, select a project in the project list, and then click the Camera Calibration (Standard) button in the toolbar. The Configuration before Calibration window will be prompted.
-
In the Select how to calibrate window, select the Load calibration parameters radio button, select the parameters that were calibrated for the project, and then click the Next button.
-
In the Select parameter usage window, select Continue working on the calibrated camera radio button, and then click the Next button.
Camera status should be displayed as connected. -
In the Select calibration task window, select Recalibrate from the start radio button, and then click the Calibration button. The Calibration (Eye in Hand) window will be prompted.
Till now, you have completed the pre-calibration configuration and can start the calibration procedure.
Calibration Procedure
Re-Calibration Procedure
By default, the camera used in the project is set to be connected. Please click the Next button to continue the calibration procedure.
If the camera is not connected, please complete the camera connection by referring to the following instructions:
-
In the Connect to camera step, select the camera to connect in the Camera ID list, and then click the button or double-click the camera entry to connect to it.
-
After the camera is connected, click the Capture live or Capture once button.
-
In the Image viewer panel, ensure that the camera can capture images normally and click the Next button on the bottom bar.
Mount Calibration Board & Check Intrinsic Parameters
-
In the Mount calibration board & check intrinsic parameters step, select the calibration board model for the Standard calibration board model parameter according to its model nameplate in the 1 Select calibration board area.
-
In the 2 Check calibration board position and point cloud quality area, read carefully the requirements on the calibration board position and point cloud quality, and then click the Capture live button. The Capture live button will turn into Stop capturing and detect position.
-
Manually move the calibration board to the proper position (in the red rectangle), and ensure that the 2D image and depth map of the calibration board meet the requirements, and then click the Stop capturing and detect position button.
If the captured images do not meet the requirements, click the Open Mech-Eye Viewer button to open the Mech-Eye Viewer software, adjust the 2D and 3D exposure parameters and re-capture images. Please note that you need to change the Parameter group parameter to “calib” first.
-
In the 3 Check intrinsic parameters area, click the Check intrinsic parameters button.
-
Confirm the results of the camera intrinsic parameter check.
-
If the camera intrinsic parameter check passes, click the OK button in the prompted window, and then click the Next button on the bottom bar.
-
If the camera intrinsic parameter check fails, adjust detection parameters by drawing aid circles or manually adjusting the calibration circle detection parameters, and then click the Recheck intrinsic parameters button. If the intrinsic parameter check still fails, please contact Technical Support.
-
Draw Aid Circle
-
To draw an aid circle, click the Draw an aid circle button.
-
In the right Image viewer panel, right-click the calibration board image, clear the Fit to window checkbox, press the Ctrl key and drag the roller to adjust the image to a suitable size.
-
Move the mouse pointer to the cross center point of the calibration circle, press the left mouse button and make the aid circle completely include the calibration circle and then release it.
-
Click the Recheck intrinsic parameters button, and confirm that the camera intrinsic parameter check passes.
Collect Images and Flange Poses
-
In the Collect images and flange poses step, select the Save images checkbox.
-
Control the robot to move to different calibration points and then click the Add an image and record flange pose button.
Please refer to the calibration point poses recorded during the project deployment phase for the robot’s movement calibration. -
In the prompted window, enter the robot flange pose.
-
Confirm that the number of the currently recognized calibration circles meets the requirements, and then click the Next button on the bottom bar.
Calculate Extrinsic Parameters
-
In the Calculate extrinsic parameters step, click the Calculate extrinsic parameters button.
-
In the prompted window indicating calibration success, click the OK button.
-
Calculate the Z-axis translation of the extrinsic parameters.
Due to the lack of degrees of freedom in rotation in four-axis robots, the captured images during calibration may lack the images for calibration board rotation. After calibration, you need to manually adjust the Z-axis value of the extrinsic parameters. -
Mount a tip on the proper position of the robot gripper, and set the tool center point (TCP).
-
Control the robot to let its end tip touch the cross center point of a calibration circle on the calibration board, and record the tool pose (X0, Y0, Z0) in the teach pendant.
-
Move the robot to the image-capturing position to capture the image of the calibration board, click the Apply parameters and preview point cloud button in the Adjust parameters area to send the point cloud of the calibration board to Mech-Viz.
-
In Mech-Viz, add a “Fixed-Point Move” Step, and enter the tool pose (X0, Y0, Z0) in the previous step as the target waypoint. Adjust the Z-axis value of the tool pose to make sure that the target waypoint has moved to the surface of the calibration board’s point cloud, and record the new Z-axis value (Z1). You can get the Z-axis value error ΔZ by subtracting Z1 from Z0.
-
Back to the Adjust parameters area of the Calculate extrinsic parameters steps, manually change the Z-axis translation parameter to the error ΔZ, and then click the Apply parameters and preview point cloud button.
-
In the 3D Simulation Area of Mech-Viz, confirm that the pose (X0, Y0, Z0) is on the surface of the calibration board’s point cloud.
-
-
After calculating the extrinsic parameters, click Point cloud viewer on the right to view the error point cloud.
The error point cloud shows the deviation between the calculated value and the actual value of the circles on the calibration board. -
Verify whether the accuracy of the calibrated extrinsic parameters meets the project’s requirements. The error value with the 100% percentage can be roughly considered as the calibration accuracy.
-
Click the Save button on the bottom bar. In the prompted Save Calibration Files dialog box, click the OK button. The camera calibration result will be automatically saved in the “calibration” directory of the project.
Till now, the calibration process is completed.
Verify Calibration Results
After calculating the extrinsic parameters, you can use any of the following methods to verify if the calibration results are valid.
View the Extrinsic Parameter Calibration Report
After calculating the extrinsic parameters, you can click View extrinsic parameter calibration report button. The extrinsic parameter calibration report will be automatically displayed after it is generated.
If the calibration results of the Euler angle convention check, camera accuracy check, and robot absolute accuracy check are all “Pass” (or there is no significant error), then the extrinsic parameters are calibrated successfully and can be used.
If any of the checks fails, please follow the recommendations provided in the report and re-calibrate the extrinsic parameters until the check passes.
Use the “Analyze Extrinsic Parameter Error in EIH Setup” Tool to Evaluate Extrinsic Parameters
After calculating the extrinsic parameters, you can use the “Analyze extrinsic parameter error in EIH setup” tool to evaluate whether the calibration results are valid.
The detailed instructions are as follows:
-
In the Calculate extrinsic parameters step, click Extrinsic parameter accuracy in the Supplementary tools area, and then select Analyze extrinsic parameter error in EIH setup in the pop-up Error Analysis window.
-
Learn the instructions on evaluating the extrinsic parameter error in EIH setup, and then click the Next button.
-
Click + to add multiple sets of calibration board poses.
-
Click the Analyze error button to view the result.
If the error meets the requirements of the picking accuracy, the calibration result is valid.
Change the Extrinsic Parameter File
After hand-eye calibration, it is necessary to change the extrinsic parameter file used in the current Mech-Vision project to a new one.
-
Select the Capture Images from Camera Step.
-
In the Step Parameters panel, click of the Camera Calibration Parameters parameter, and select the newly calibrated extrinsic parameter file.