Set up Standard Interface Communication with ELITE

You are currently viewing the documentation for version 1.8.1. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

This topic introduces the process of setting up the Standard Interface communication with an ELITE robot.

Check Controller and Software Compatibility

  • Controller system software version: 2.17 or above. Can be checked in System  System info.

    elite check version1
  • Mech-Vision & Mech-Viz version : 1.7.0 or above

Set up the Network Connection

Plug the Ethernet cable into an Ethernet port on the IPC and the LAN port inside the controller.

hardware connection

Modify the IP Address

You can change the IP address of either of the following ports, to make sure the IP addresses of the two are in the same subnet.

  • The LAN port inside the controller

  • The IPC Ethernet port connected to the controller

Follow these steps to change the IP address of the controller LAN port.

  1. Turn the key to TEACH, and check if the current user account is Admin in the lower left. If it’s not Admin, press the user account and select Admin. Then, enter the password (default password: 333333) and press OK.

  2. Select System  System setting  Network setting.

    change ip 1
  3. Set the IP address. Then, press Save to save the change.

    change ip 2

Set up “Robot Communication Configuration”

  1. Run Mech-Vision, and you may enter different interfaces. Create a new solution according to the instructions below.

    • If you have entered the Welcome interface, click New blank solution.

    create solution 1
    • If you have entered the main interface, click File  New Solution on the menu bar.

    create solution 2
  2. Click Robot Communication Configuration on the toolbar of Mech-Vision.

  3. In the Robot Communication Configuration window, complete the following configurations.

    1. Click the Select robot drop-down menu, and select Listed robot. Click Select robot model, and select the robot model that you use. Then, click Next.

    2. In the Communication mode area, select Standard Interface for Interface service type, TCP Server for Protocol, and ASCII for the protocol format.

    3. It is recommended to set the port number to 50000 or above. Ensure that the port number is not occupied by another program.

    4. (Optional) Select Auto enable interface service when opening the solution.

    5. Click Apply.

      tcp ascii
  4. On the main interface of Mech-Vision, make sure that the Robot Communication Configuration switch on the toolbar is flipped and has turned blue.

    interface service

Load the Program Files

Load the Standard Interface program files to the robot with the following steps.

  1. Copy the rbctrl folder from Mech-Center\Robot_Interface\ELITE in the installation directory of Mech-Vision & Mech-Viz installed, and paste it into the flash drive.

  2. Insert the flash drive to the USB port on the controller.

  3. On the teach pendant, press System  File recovery  JBI file import, and select OK in the pop-up window.

    elite load1
    elite load2
  4. Press System  File recovery  Script update, and select OK in the pop-up window.

    elite load3
    elite load4
  5. Press Extension  Lua script.

    elite load5
  6. Change the Switch for Script1 to Open, and then select mm_elite_module for Script file.

    elite load6

Test Robot Connection

Set IPC IP Address and Port Number in Robot

Follow these steps to set the IP address and port number of the IPC in the robot global variables.

  1. Press Monitor  Global variable  Var_B.

    test connection1
  2. Change the value of variables B100 to B104. Select a variable and then press Modify in the lower left. Press Done after changing the value.

    B100 to B103 corresponds to the IP address, and B104 corresponds to the port number. The IP address displayed in the following image is 192.168.0.56, and the port number is 50000.

    test connection2
  3. After setting the IP address and port number, press Quit in the lower right. Press Save in the lower left, and select OK in the pop-up window.

    test connection3
    test connection4

Run the Program

  1. On the teach pendant, press Save  Run, and select OK in the pop-up window.

    run program1
  2. If the robot is successfully connected to the IPC, the log on the teach pendant will display a Connect Success message.

    run program2
  3. If the robot is connected successfully, the Console tab of Mech-Vision’s Log panel will display a note.

    vision center log