Master-Control Communication Setup (SIASUN GCR)

You are currently viewing the documentation for version 1.8.1. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

This guide shows you how to set up Master-Control communication with a SIASUN GCR robot.

Check Hardware and Software Versions

  1. Controller version: 2.7.0 or above (2.7.0 tested)

    Instructions
    1. Click the profile icon in the upper right corner of the teach pendant, and select About in the drop-down menu.

      controller version 1
    2. Software Version is the controller version.

      controller version 2
  2. Mech-Vision & Mech-Viz versions: 1.8.0 or above

Set up Network Connection

  1. Plug the other side of the IPC’s Ethernet cable into the Ethernet port of the robot controller.

  2. Check the robot’s IP address and make sure it is on the same subnet as the IPC.

    Instructions
    1. Click the user profile icon in the upper-right corner of the teach pendant. Click System Setting in the drop-down menu.

      ip setting 1
    2. In the System Setting window, click Network. Check the robot’s IP address and subnet mask in the Local IP area.

      ip setting 2
  3. If the IP address of the robot and that of the IPC are in different subnets, modify the IPC’s IP address.

Test Master-Control Communication

Create a Mech-Viz Project

  1. Open Mech-Viz, press Ctrl+N on the keyboard to create a new project. Select the robot model corresponding to your real robot brand and model on the interface as shown below.

    Unnamed image
  2. Press Ctrl+S and create or select a folder to save the project.

  3. Right-click the project name in the left panel in Mech-Viz and select Autoload Project.

    Unnamed image

Connect to the Robot

  1. Click Master-Control Robot on the toolbar of Mech-Viz.

  2. Input the IP address of the real robot in Robot IP address (the IP address in the picture is only an example). Click Connect the robot.

    Unnamed image

    If Mech-Viz successfully connects the real robot, the current status will change to Connected. Meanwhile, the icon in the toolbar will turn from blue to green.

    Unnamed image

    If the connection fails, please double-check the robot IP address.

Move the Robot

  1. In the toolbar of Mech-Viz, change the “Vel.” (velocity) and “Acc.” (acceleration) parameters to 5%.

    Unnamed image
  2. Click Sync Robot in the toolbar, and you can synchronize the poses of the simulated robot in the 3D simulation space with the poses of the real robot. Then click Sync Robot again to unselect it.

    Unnamed image
  3. In the Robot tab, slightly adjust the value of “J1”, for example, from 0˚ to 3˚. This operation will move the simulated robot.

    Unnamed image
  4. Click Move real robot and check if the real robot has moved. If the real robot has reached the JPs set for the simulated robot, the master-control communication is working.

    When moving the robot, please ensure the safety of personnel. In the case of an emergency, press the emergency stop button on the teach pendant!
    Unnamed image

We Value Your Privacy

We use cookies to provide you with the best possible experience on our website. By continuing to use the site, you acknowledge that you agree to the use of cookies. If you decline, a single cookie will be used to ensure you're not tracked or remembered when you visit this website.