Scan Mode

You are currently viewing the documentation for the latest version (2.4.1). To access a different version, click the "Switch version" button located in the upper-right corner of the page.

■ If you are not sure which version of the product you are currently using, please feel free to contact Mech-Mind Technical Support.

This topic introduces how to adjust the parameters in the scan mode, in order to obtain the satisfactory intensity image, depth map, and point cloud.

Before reading this topic, please read Adjust Parameters first.

Determine Data Quality

Determine the data quality based on the following criteria. If the data quality is not good, adjust the parameters according to the next section.

Intensity image, depth map and point cloud: the needed data is complete. The following table uses point clouds as examples.

Data is complete Data is incomplete

proper cloud

improper cloud 1

improper cloud 2

Adjust Parameters in Scan Mode

Please follow the procedure below to adjust the parameters in the scan mode. After adjusting parameters, acquire data again to check if the data quality changes.

For the methods of triggering the laser profiler to acquire data in the scan mode, please refer to Methods for Triggering Data Acquisition and Workflow of Triggering Data Acquisition.
  1. Adjust the rate at which scanning is triggered:

    Scanning triggered by encoder

    Adjust parameters in the Encoder Settings category.

    Scanning triggered at fixed-rate

    Adjust Trigger Rate.

  2. Set the parameters in the Scan Settings category.

  3. Adjust the following parameters to resolve common issues:

    • If vibration along the X-axis direction results in distortion of the edges of the target object in the intensity image, depth map, and point cloud, adjust X-Axis Profile Alignment.

    • If vibration along the Z-axis direction results in distortion of the surfaces of the target object in the intensity image, depth map, and point cloud, adjust Z-Axis Profile Alignment.

    • If the depth map and point cloud contains noise or false data, adjust the parameters in the Filters category.

  4. (Optional) Adjust the aspect ratio of the point cloud through Point Cloud Y-Axis Resolutions.