Only One of Multiple Laser Profilers Could Be Discovered

You are currently viewing the documentation for version 2.3.4. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

Symptom

Multiple laser profilers are connected to the computer, but only one of the laser profilers could be discovered by Mech-Eye SDK or the GenICam client.

Possible Causes

The laser profiler IP address is the same as the IP address of the computer Ethernet port connected to it.

Solutions

Please follow these steps to troubleshoot the issue:

  1. Check if the following two IP addresses are identical:

    The IP address of the laser profiler that could be discovered

    The IP address of the computer Ethernet port connected to this laser profiler

    • If not, please contact Technical Support.

    • If so, proceed to step 2.

  2. Modify the IP address of the laser profiler or the computer Ethernet port, and then check if the other laser profilers can be discovered by Mech-Eye SDK or the GenICam client.

    Modify the laser profiler IP address

    Use Mech-Eye Viewer or the IP configuration tool to modify.

    Modify the IP address of the computer Ethernet port

    Refer to Set IP Address on Computer.

    • If all laser profilers could be discovered, the troubleshooting is completed.

    • If not all laser profilers could be discovered, please contact Technical Support.