LNX-8000 Series
Sensor Head
Model | LNX-8030 | LNX-8080 | LNX-8300 | ||
---|---|---|---|---|---|
Data points per profile |
4096 |
||||
Scan rate(1) |
3.3–15 kHz |
||||
RD |
78 mm |
250 mm |
325 mm |
||
Measurement range |
Z-axis |
30 mm |
100 mm |
305 mm |
|
X-axis |
Near |
33 mm |
76 mm |
230 mm |
|
RD |
35 mm |
89 mm |
310 mm |
||
Far |
37 mm |
96 mm |
430 mm |
||
X-axis resolution |
9 μm |
23.5 μm |
105 μm |
||
Z-axis repeatability |
0.2 μm |
0.5 μm |
2 μm |
||
Z-axis linearity |
± 0.02% of F.S. |
||||
Weight |
0.9 kg |
1.2 kg |
1.2 kg |
||
Dimensions |
133 × 61 × 102 mm |
182 × 63 × 112 mm |
195 × 61 × 109 mm |
||
Light source |
Blue laser (405 nm) |
||||
Laser class |
Class 2 |
Class 2M |
|||
Lens inclination(2) |
30° |
22° |
19° |
||
Operating temperature(3) |
0–45°C |
||||
Safety and EMC |
CE/FCC/VCCI/KC/ISED/NRTL |
||||
IP rating(4) |
IP67 |
||||
Cooling |
Passive |
(1) The maximum scan rate reachable is 3.3 kHz when Z-Direction ROI is set to 1 and 15 kHz when Z-Direction ROI is set to 1/16.
(2) Please refer to the diagrams in Field of View.
(3) This is the range when the sensor head is mounted on a metal frame and the heat from the sensor head is well dissipated.
(4) Test implemented based on IEC 60529. 6: dust-tight; 7: protected against the effects of temporary immersion in water.
Controller Port
No. | Name | Function | Description |
---|---|---|---|
1 |
GigE_MX1+ |
Ethernet signal line |
2.5GigE |
2 |
GigE_MX1- |
Ethernet signal line |
2.5GigE |
3 |
GigE_MX2+ |
Ethernet signal line |
2.5GigE |
4 |
GigE_MX2- |
Ethernet signal line |
2.5GigE |
5 |
GigE_MX3+ |
Ethernet signal line |
2.5GigE |
6 |
GigE_MX3- |
Ethernet signal line |
2.5GigE |
7 |
GigE_MX4+ |
Ethernet signal line |
2.5GigE |
8 |
GigE_MX4- |
Ethernet signal line |
2.5GigE |
9 |
DC_12V |
12 V power supply |
Max. rated current: 2 A |
10 |
DC_0V |
12 V power supply return line |
Max. rated current: 2 A |
11 |
Trigger |
Trigger signal input |
Low speed |
12 |
DIR |
Direction signal input |
Low speed |
Controller
Model | LNX-8000C |
---|---|
Weight |
1.2 kg |
Dimensions |
204 × 48.2 × 166 mm |
Input voltage |
24 VDC ± 10% |
Rated current |
2 A |
Max. power |
48 W |
Communication interface |
Gigabit Ethernet |
Encoder Input |
Single-ended and differential encoders supported |
Operating temperature |
0–45°C |
Storage temperature |
-30–70°C |
Safety and EMC |
CE/FCC/VCCI/KC/ISED/NRTL |
Cooling |
Passive |
Sensor Head Port
No. | Name | Function | Description |
---|---|---|---|
1 |
GigE_MX1+ |
Ethernet signal line |
2.5GigE |
2 |
GigE_MX1- |
Ethernet signal line |
2.5GigE |
3 |
GigE_MX2+ |
Ethernet signal line |
2.5GigE |
4 |
GigE_MX2- |
Ethernet signal line |
2.5GigE |
5 |
GigE_MX3+ |
Ethernet signal line |
2.5GigE |
6 |
GigE_MX3- |
Ethernet signal line |
2.5GigE |
7 |
GigE_MX4+ |
Ethernet signal line |
2.5GigE |
8 |
GigE_MX4- |
Ethernet signal line |
2.5GigE |
9 |
DC_12V |
12 V power supply |
Max. rated current: 2 A |
10 |
DC_0V |
12 V power supply return line |
Max. rated current: 2 A |
11 |
Trigger |
Trigger signal output |
Low speed |
12 |
DIR |
Direction signal output |
Low speed |
Input Signal Terminals
No. | Name | Description |
---|---|---|
1 |
IN1 |
Universal digital input 1, optocoupler isolation, bidirectional input optocoupler. |
2 |
IN2 |
Universal digital input 2, optocoupler isolation, bidirectional input optocoupler. |
3 |
IN3 |
Universal digital input 3, optocoupler isolation, bidirectional input optocoupler. |
4 |
IN4 |
Universal digital input 4, optocoupler isolation, bidirectional input optocoupler. |
5 |
IN5 |
Universal digital input 5, optocoupler isolation, bidirectional input optocoupler. |
6 |
IN6 |
Universal digital input 6, optocoupler isolation, bidirectional input optocoupler. |
7–8 |
RESERVED |
Reserved terminals. |
9 |
LEVELCONTROL_ENABLE |
LOW level: Only MEASURE_START controls data acquisition; HIGH level: both MEASURE_START and MEASURE_STOP controls data acquisition. Optocoupler isolation, bidirectional input optocoupler. |
10 |
MEASURE_START |
Input signal to start acquisition, optocoupler isolation, bidirectional input optocoupler. |
11 |
MEASURE_STOP |
Input signal to stop acquisition, optocoupler isolation, bidirectional input optocoupler. |
12 |
RESERVED |
Reserved terminals. |
13–16 |
COM_IN |
Common terminals for input signal. |
|
Output Signal Terminals
No. | Name | Description |
---|---|---|
17–20 |
COM_OUT |
Common terminals for output signal. |
21 |
O1 |
Universal digital output 1, optocoupler isolation, NPN output. |
22 |
O2 |
Universal digital output 2, optocoupler isolation, NPN output. |
23 |
O3 |
Universal digital output 3, optocoupler isolation, NPN output. |
24 |
O4 |
Universal digital output 4, optocoupler isolation, NPN output. |
25 |
O5 |
Universal digital output 5, optocoupler isolation, NPN output. |
26 |
O6 |
Universal digital output 6, optocoupler isolation, NPN output. |
27 |
O7 |
Universal digital output 7, optocoupler isolation, NPN output. |
28 |
O8 |
Universal digital output 8, optocoupler isolation, NPN output. |
29 |
READY |
Acquisition ready signal, optocoupler isolation, NPN output. |
30 |
ERROR |
Acquisition error signal, optocoupler isolation, NPN output. |
31 |
TRG_ERROR |
Error signal when start signal is received again after acquisition, optocoupler isolation, NPN output. |
32–36 |
RESERVED |
Reserved terminals. |
For explanations of the READY, ERROR and TRG_ERROR terminals, please refer to Provide Data Acquisition Status Signals to External Device. |
Encoder Signal Terminals
No. | Name | Description |
---|---|---|
37 |
A1+ |
Differential encoder A+ input, optocoupler isolation, RS-422 standard differential input. |
38 |
A1- |
Differential encoder A- input, optocoupler isolation, RS-422 standard differential input. |
39 |
B1+ |
Differential encoder B+ input, optocoupler isolation, RS-422 standard differential input. |
40 |
B1- |
Differential encoder B- input, optocoupler isolation, RS-422 standard differential input. |
41 |
Z1+ |
Differential encoder Z+ input, optocoupler isolation, RS-422 standard differential input. |
42 |
Z1- |
Differential encoder Z- input, optocoupler isolation, RS-422 standard differential input. |
43 |
A2+24 |
Single-ended encoder A+ input, 24 V, optocoupler isolation. |
44 |
A2+12 |
Single-ended encoder A+ input, 12 V, optocoupler isolation. |
45 |
A2+5 |
Single-ended encoder A+ input, 5 V, optocoupler isolation. |
46 |
A2- |
Single-ended encoder A- input, common, optocoupler isolation. |
47 |
B2+24 |
Single-ended encoder B+ input, 24 V, optocoupler isolation. |
48 |
B2+12 |
Single-ended encoder B+ input, 12 V, optocoupler isolation. |
49 |
B2+5 |
Single-ended encoder B+ input, 5 V, optocoupler isolation. |
50 |
B2- |
Single-ended encoder B- input, common, optocoupler isolation. |
51 |
Z2+24 |
Single-ended encoder Z+ input, 24 V, optocoupler isolation. |
52 |
Z2+12 |
Single-ended encoder Z+ input, 12 V, optocoupler isolation. |
53 |
Z2+5 |
Single-ended encoder Z+ input, 5 V, optocoupler isolation. |
54 |
Z2- |
Single-ended encoder Z- input, common, optocoupler isolation. |
55 |
R1 |
RS-232 serial interface 1, input, magnetic isolation. |
56 |
T1 |
RS-232 serial interface 1, output, magnetic isolation. |
57 |
G1 |
RS-232 serial interface 1 ground reference. |
58 |
G2 |
RS-232 serial interface 2 ground reference. |
59 |
R2 |
RS-232 serial interface 2, input, magnetic isolation. |
60 |
T2 |
RS-232 serial interface 2, output, magnetic isolation. |