Set Laser Profiler IP Address and Connect to Laser Profiler

You are currently viewing the documentation for version 2.3.1. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

For Mech-Eye Viewer to connect to the laser profiler successfully, please make sure that the following IP addresses are unique and in the same subnet.

After setting the IP addresses, you can connect to the laser profiler. Once the laser profiler is connected, you can set a custom name for it for easy recognition of different devices.

If the laser profiler to be connected is not displayed in Mech-Eye Viewer, please refer to Laser Profiler Not Found in Mech-Eye SDK.

Set Laser Profiler IP Address

You can set a static IP address for the laser profiler, or dynamically assign the IP address.

The factory IP configurations of the laser profiler is as follows:

If you are using multiple laser profilers, please modify the laser profiler IP addresses first. Otherwise, issues such as disconnection will occur.

IP address assignment method

Static

IP address

192.168.23.203

Subnet mask

255.255.255.0

Gateway

0.0.0.0

Set Static IP address

Record the set laser profiler IP address for future reference.

Follow these steps to set a static IP address for the laser profiler:

  1. Open Mech-Eye Viewer, select the info card of the laser profiler to be connected, and click setting in the upper right of the card to open the IP Configuration window.

  2. Select Set as Static IP.

  3. Based on the IP address and subnet mask displayed in Computer IP Configuration, select IP Address Class, and enter the laser profiler IP address and subnet mask.

    • The IP address must be unique.

    • The Computer IP Configuration section displays the IP address and subnet mask of the computer Ethernet port connected to the laser profiler.

  4. Click Apply to apply the modified IP configuration.

    After you click Apply, it will take about 5 min for Mech-Eye Viewer to check the availability of the new IP address.

Using dynamic IP address

Follow these steps to dynamically assign an IP address to thelaser profiler:

  1. Open Mech-Eye Viewer, select the info card of the laser profiler to be connected, and click setting in the upper right of the card to open the IP Configuration window.

  2. Select Set via DHCP and click Apply.

If you want to set the IP address of the computer Ethernet port connected to the laser profiler, please refer to Set IP Address on Computer.

Connect to Laser Profiler

When the laser profiler info card displays the Connect button, click this button to connect to the laser profiler.

connected view
For the very first time that the laser profiler is connected to the computer, it may take up to a few minutes for the laser profiler to show up in Mech-Eye Viewer.

If other content is displayed, please complete the corresponding action according to the following table, and then connect to the laser profiler.

Displayed content Description

Upgrade button

Click this button to upgrade the software or the laser profiler firmware first.

Connected

laser profiler is already connected to the GenICam client or another computer. Please disconnect laser profiler from the GenICam client or the other computer first.

cant connect

Hover the cursor here to check the cause and solution, and resolve the issue according to these.

Set a Custom Name

The laser profiler name can be used to distinguish different devices, clarifying the usages and locations of the devices, and more. Please set the custom name according to your actual needs. The custom name will be displayed in the Device List.

After connecting to the laser profiler, on the left of the data acquisition area, click icon edit or Set device name to set a custom name.

  • The following characters cannot be used: \/:*?"<>|.

  • Click the custom name again to modify it.


This topic introduced how to set the laser profiler IP address and connect to the laser profiler. After connecting to the laser profiler, you can start acquiring data. The next topic introduces the actions for acquiring data and viewing the obtained data.

We Value Your Privacy