Technical Specifications (V4)

This topic provide technical specification comparisons across the V4 cameras. For more details, please refer to the Technical Specifications section of the hardware manual for each model/series.

Technical Specification Comparisons

Model

NANO

PRO S

PRO M

UHP-140

DEEP

LSR L

Recommended working distance

300–600 mm

500–1000 mm

1000–2000 mm

300 ± 20 mm

1200–3500 mm

1200–3000 mm

FOV (near)

220 × 150 mm @ 0.3 m

370 × 240 mm @ 0.5 m

800 × 450 mm @ 1 m

135 × 90 mm @ 280 mm

1200 × 1000 mm @ 1.2 m

1200 × 1000 mm @ 1.2 m

FOV (far)

440 × 300 mm @ 0.6 m

800 × 450 mm @ 1 m

1500 × 890 mm @ 2 m

150 × 100 mm @ 320 mm

3500 × 2800 mm @ 3.5 m

3000 × 2400 mm @ 3.0 m

Depth map resolution

1280 × 1024

1920 × 1200

1920 × 1200

2048 × 1536

2048 × 1536

2048 × 1536

1024 × 768

RGB resolution

1280 × 1024

1920 × 1200

1920 × 1200

2048 × 1536

2000 × 1500

4000 × 3000

2000 × 1500

Point Z-value repeatability (σ)(1)

0.1 mm @ 0.5 m

0.05 mm @ 1 m

0.2 mm @ 2 m

2.6 μm @ 0.3 m

1.0 mm @ 3 m

0.5 mm @ 3 m

Regional Z-value repeatability (σ)(2)

-

-

-

0.09 μm @ 0.3 m

-

-

Measurement accuracy (VDI/VDE)(3)

0.1 mm @ 0.5 m

0.1 mm @ 1 m

0.2 mm @ 2 m

0.03 mm @ 0.3 m

3.0 mm @ 3 m

1.0 mm @ 3 m

Typical capture time

0.6–1.1 s

0.3–0.6 s

0.3–0.6 s

0.6–0.9 s

0.5–0.9 s

0.5–0.9 s

Weight

About 0.7 kg

About 1.6 kg

About 1.9 kg

About 1.9 kg

About 2.4 kg

About 2.9 kg

Baseline

About 68 mm

About 180 mm

About 270 mm

About 80 mm

About 300 mm

About 380 mm

Dimensions

About 145 × 51 × 85 mm

About 265 × 57 × 100 mm

About 353 × 57 × 100 mm

About 260 × 65 × 142 mm

About 366 × 77 × 92 mm

About 459 × 77 × 86 mm

Light source

Blue LED (459 nm, RG2)

Red laser (638 nm, class 2)

Operating temperature

0–45°C

-10–45°C

Communication interface

Gigabit Ethernet

Input

24 VDC, 1.5 A

24 VDC, 3.75 A

Safety and EMC

CE/FCC/VCCI/UKCA/KC

IP rating(4)

IP65

Cooling

Passive

(1) One standard deviation of 100 Z-value measurements of the same point. The measurement target was a ceramic plate.

(2) One standard deviation of 100 measurements of the difference between the Z-value means of two same-sized regions. The measurement target was a ceramic plate.

(3) According to VDI/VDE 2634 Part II.

(4) Test implemented based on IEC 60529. 6: dust-tight; 5: protected against water jets.