Technical Specifications (V4)
This topic provide technical specification comparisons across the V4 cameras. For more details, please refer to the Technical Specifications section of the hardware manual for each model/series.
Technical Specification Comparisons
Model |
NANO |
PRO S |
PRO M |
UHP-140 |
DEEP |
LSR L |
---|---|---|---|---|---|---|
Recommended working distance |
300–600 mm |
500–1000 mm |
1000–2000 mm |
300 ± 20 mm |
1200–3500 mm |
1200–3000 mm |
FOV (near) |
220 × 150 mm @ 0.3 m |
370 × 240 mm @ 0.5 m |
800 × 450 mm @ 1 m |
135 × 90 mm @ 280 mm |
1200 × 1000 mm @ 1.2 m |
1200 × 1000 mm @ 1.2 m |
FOV (far) |
440 × 300 mm @ 0.6 m |
800 × 450 mm @ 1 m |
1500 × 890 mm @ 2 m |
150 × 100 mm @ 320 mm |
3500 × 2800 mm @ 3.5 m |
3000 × 2400 mm @ 3.0 m |
Depth map resolution |
1280 × 1024 |
1920 × 1200 |
1920 × 1200 |
2048 × 1536 |
2048 × 1536 |
2048 × 1536 |
1024 × 768 |
||||||
RGB resolution |
1280 × 1024 |
1920 × 1200 |
1920 × 1200 |
2048 × 1536 |
2000 × 1500 |
4000 × 3000 |
2000 × 1500 |
||||||
Point Z-value repeatability (σ)(1) |
0.1 mm @ 0.5 m |
0.05 mm @ 1 m |
0.2 mm @ 2 m |
2.6 μm @ 0.3 m |
1.0 mm @ 3 m |
0.5 mm @ 3 m |
Regional Z-value repeatability (σ)(2) |
- |
- |
- |
0.09 μm @ 0.3 m |
- |
- |
Measurement accuracy (VDI/VDE)(3) |
0.1 mm @ 0.5 m |
0.1 mm @ 1 m |
0.2 mm @ 2 m |
0.03 mm @ 0.3 m |
3.0 mm @ 3 m |
1.0 mm @ 3 m |
Typical capture time |
0.6–1.1 s |
0.3–0.6 s |
0.3–0.6 s |
0.6–0.9 s |
0.5–0.9 s |
0.5–0.9 s |
Weight |
About 0.7 kg |
About 1.6 kg |
About 1.9 kg |
About 1.9 kg |
About 2.4 kg |
About 2.9 kg |
Baseline |
About 68 mm |
About 180 mm |
About 270 mm |
About 80 mm |
About 300 mm |
About 380 mm |
Dimensions |
About 145 × 51 × 85 mm |
About 265 × 57 × 100 mm |
About 353 × 57 × 100 mm |
About 260 × 65 × 142 mm |
About 366 × 77 × 92 mm |
About 459 × 77 × 86 mm |
Light source |
Blue LED (459 nm, RG2) |
Red laser (638 nm, class 2) |
||||
Operating temperature |
0–45°C |
-10–45°C |
||||
Communication interface |
Gigabit Ethernet |
|||||
Input |
24 VDC, 1.5 A |
24 VDC, 3.75 A |
||||
Safety and EMC |
CE/FCC/VCCI/UKCA/KC |
|||||
IP rating(4) |
IP65 |
|||||
Cooling |
Passive |
(1) One standard deviation of 100 Z-value measurements of the same point. The measurement target was a ceramic plate.
(2) One standard deviation of 100 measurements of the difference between the Z-value means of two same-sized regions. The measurement target was a ceramic plate.
(3) According to VDI/VDE 2634 Part II.
(4) Test implemented based on IEC 60529. 6: dust-tight; 5: protected against water jets.