Perform Dataset Testing in Batches under Operation Mode

You are currently viewing the documentation for version 2.4.2. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

Introduction

You can perform batch-wise testing on the dataset under the Operation Mode. This feature is for the Defect Segmentation module and the Classification module. It is unavailable under the cascade mode.

After the model training is complete, click Tools  Operation Mode. You can turn on the Operation Mode to import a large amount of new data for testing and perform manual re-judgment. After the testing is complete, you can output a report, which contains information including accuracy, false positive rate, and false negative rate.

The Classification module only presents the accuracy.

Steps

  1. Select Data Source

    If you need to use the operations mode to demonstrate the model effect, select Mech-DLK as the data source. If you need to import a large amount of new data for testing, select Folder as the data source.

    Mech-DLK

    Directly import all image datasets in the current project.

    Folder

    After selecting the image folder path, import all images in the folder as a new dataset. The new dataset imported will be independent of the original datasets in the project.

    Before the Operation Mode is turned on, if some new image data is imported into the project in addition to the training set and validation set of the current project, then when the data source of the Operation Mode is Mech-DLK, those new image data will also be read.
  2. Defect Detection Settings

    Please set each parameter according to the defect judgment standard, and the defect filtering options will be enabled simultaneously in the software. The defect detection settings are independent of the defect judgment rules set for validation of the Defect Segmentation module.

  3. Load Model

    Click Load Model. After loading successfully, click Next to enter the inference interface.

  4. Make Inference and Export Report

    Click the Start button under Auto infer to start inference. After the automatic inference is completed, check whether the result is accurate, and click the corresponding button under Manual check. After completing the manual check, click Export report to view information including the accuracy, false positive rate, and false negative rate.

The Classification module only presents the accuracy.