Image Data Not Found in Virtual Mode of Step “Capture Images from Camera”

You are currently viewing the documentation for version 1.7.5. To access documentation for other versions, click the "Switch Version" button located in the upper-right corner of the page.

■ To use the latest version, visit the Mech-Mind Download Center to download it.

■ If you're unsure about the version of the product you are using, please contact Mech-Mind Technical Support for assistance.

Symptom:

In the virtual mode of Step “Capture Images from Camera”, the error message “No color images” was displayed when selecting the image data.

Affected Software Versions:

All Mech-Vision versions.

Possible Cause:

Image files are not named properly.

Solution:

When images are read in the virtual mode of Step “Capture Images from Camera”, the naming conventions below for the images should be followed. The serial number of the color image should be the same as its depth map counterpart.

  • Color images: rgb_image_xxxx.jpg;

  • Depth maps: depth_image_xxxx.png.