Obtain Results
Obtain Inspection Result of Pin Positions
It is impossible to set a unified acceptable range for multiple pins as the distance to the reference lines varies. Therefore, you need to use the Evaluate Values in List Step to set an acceptable range for each pin.
The Evaluate Values in List Step can only take zero-dimensional data, while the measured plane distance is a one-dimensional list. Thus, you need to use the Extract Data Step for dimensionality reduction. |
The detailed instructions are as follows:
-
In the Parameters section of the Extract Data Step, set the “Dimension” to 1, and use the range to extract the distance of the eight pins to the reference line.
-
In the Parameters section of the Evaluate Values in List Step, set the “Evaluation Mode” to Custom, and accurately enter the number of measured values, i.e., 8. Then, open the editor to set acceptable distance range for each pin.
-
Finally, in the Output section of the Evaluate Values in List Step, select NG Count, and set both the “Max” and “Min” of the item to 0, namely, no NG value.
Run the Step, and you can check the inspection result of pin position in the Output Results panel at the bottom of the visualization area.
No NG values detected, and thus the inspection result of the output item is OK.
Obtain Inspection Result of Connectors
The inspection result of connectors depends on the pin position result, that is, the overall judgment result of the project. Click the Output Management button from the toolbar of the home interface to set quality judgment rules for the project.
Select the project under the Quality judgment tab, set the “Judgment type” to Comprehensive, and select the output item corresponding to the pin height inspection result.
Example:
Then, click the Apply button to save the settings. Run the project, and you will obtain the judgment result of the project in the upper-left corner of the graphical programming workspace.
|
(Optional) Send Measurement and Inspection Results to External Devices
If you need to send the measurement and inspection results to an external device, you can configure the settings under the Communication output tab in the “Output Management” window.
Click the + Add button to select the data to be output to an external device according to the actual needs.
|
Up to now, you have finished the deployment of the pin position inspection solution.