Set up Standard Interface Communication with ABB¶
This topic introduces the process of setting up the Standard Interface communication with an ABB robot.
The process consists of the following steps:
Please have a flash drive ready at hand.
Check Controller and Software Compatibility¶
Compatibility requirements are as follows:
Robot: a 4-axis or 6-axis ABB robot
RobotWare Option: 616-1 PC Interface
Set up the Network Connection¶
Hardware Connection¶
Plug the Ethernet cable of the IPC into the X6 (WAN) port of the robot controller, as shown below.
Hint
If you only need to load the program files via RobotStudio, you can use either LAN port or WAN port to connect the robot controller. However, in order to enable visual communication, the Ethernet cable can only be connected to the WAN port.
IP Address Configuration¶
You can set the IP on the teach pendant or via RobotStudio.
Set the IP on the teach pendant
-
Select Advanced…
Select Start Boot Application and tap Next.
Select Start Boot Application to confirm.
After restarting, you will see the interface as shown below. Tap Settings.
Select Use the following IP settings and configure the IP Address, Subnet Mask, and Default gateway. Tap OK after configuration.
Tap Select System.
Select the system name in Installed Systems box and then tap Select. Tap OK after configuration.
Select Restart Controller.
Tap OK to proceed.
-
Set the IP via RobotStudio
Follow the steps as shown in the figure below to configure the robot IP, and restart the robot after configuration.
Go to
to check if the IP configuration was successful after restarting.
Set up “Robot and Interface Configuration” in Mech-Vision¶
Click Robot and Interface Configuration on the toolbar of Mech-Vision.
Select Listed robot from the Select robot drop-down menu, and then click Select robot model.
Select the robot model that you use, and then click Next.
Select the following options and click Apply.
Interface Type: Standard Interface
Protocol: TCP Server and HEX-Little endian
Make sure the Interface Service is started: on the toolbar of Mech-Vision, the Interface Service switch on the far right is flipped and turned to blue.
Load the Program Files¶
Attention
Before operating the robot, please follow the backup instructions below to back up the system.
Back up Robot Programs¶
Go to the home page using the menu in the upper-left corner, and then select Backup and Restore.
Select Backup Current System….
Specify the backup file name by pressing on ABC…, and specify the directory for saving the file by pressing …. Then, press Backup in the lower right to start the backup process.
Prepare the Files¶
Copy MM_Module.mod and MM_Auto_Calib.mod from xxx\Mech-Mind Software Suite-x.x.x\Mech-Center\Robot_Interface\ABB and paste them into the flash drive.
Hint
MM_Module.mod and MM_Auto_Calib.mod are program module files.
Load the Files to the Robot¶
You can load the program modules (i.e., MM_Module.mod and MM_Auto_Calib.mod) with the teach pendant or via RobotStudio.
Load the modules with the teach pendant
Insert the flash drive into the USB port of the teach pendant.
Go to
.Select T_ROB1 and tap Show Modules.
Select
.Select the module in the USB flash drive one at a time and tap OK to load the module.
Select Yes in the pop-up window to confirm adding a new module.
After loading successfully, you can see the two modules in T_ROB1.
Load the modules via RobotStudio
Insert the flash drive into the USB port of the computer.
Open RobotStudio and connect the robot.
Request write access: click Request Write Access in RobotStudio, and press Grant on the teach pendant.
Click on Controller and right click on T_ROB1. Select Load Module in the context menu, and then open the two modules, as shown below.
If MM_Module.mod and MM_Auto_Calib.mod appear in T_ROB1, the modules are loaded successfully.
Further Configurations¶