Complete Calibration in Eye to Eye Scenario

This how-to guide introduces how to complete the hand-eye calibration in the Eye to Eye scenario.

Note

For more information about calibration in the Eye to Eye scenario, please refer to Eye to Eye Calibration .

Preparation before Calibration

Before hand-eye calibration, you need to finish the following preparations:

  • Construct the Mech-Mind Vision System.

  • Prepare the materials required for calibration.

  • Adjust the effect of calibration board’s point cloud.

  • Complete the robot and communication configuration.

Construct the Mech-Mind Vision System

Construct the Mech-Mind Vision System by referring to the section Construct Mech-Mind Vision System.

You need to use Mech-Eye Viewer, Mech-Center, Mech-Vision and Mech-Viz during hand-eye calibration. Please ensure that they have been installed and are running the latest versions.

Prepare the Materials Required for Calibration

The hand-eye calibration in the Eye to Eye scenario needs to use the calibration board. Please prepare the calibration board according to the following requirements:

  • Ensure that the circles of the calibration board are clearly visible and without obvious scratches, and the board does not suffer from deformations.

  • In the Eye to Eye scenario, mount the robot-specific bracket for calibration board onto the robot flange, and then mount the calibration board onto the bracket. Make sure that the calibration board is attached securely, and that the board is parallel to the XY plane of the robot flange frame.

    Note

    If an undetachable gripper is connected to the robot flange, you can attach the calibration board directly to the gripper.

In addition, before calibration, move the robot to the starting point for calibration, that is, the bottom middle of the overlapped area of the two cameras’ field of view.

Adjust the Effect of Calibration Board’s Point Cloud

  1. Open Mech-Eye Viewer to adjust camera parameters.

  2. Adjust 2D parameters to make sure that the 2D image of the calibration board is clear and neither overexposed nor underexposed.

  3. Adjust 3D parameters to make sure that the point clouds of the circles on the calibration board are complete and have clear contours. It is recommended to set Point Cloud Smoothing and Outlier Removal to Normal in the Point Cloud Processing section to reduce the point cloud fluctuation range.

    Note

    If the on-site ambient lights are not ideal and affect the quality of 2D images and point clouds, you can use shading or supplemental light to improve the lighting conditions.

  4. Make sure the obtained point clouds of the circles on the calibration board are complete and have clear contours, as shown in the following figure.

../../_images/clear-board.png

Hint

Because the 2D image type in the calibration process is the internal IR image, the captured image and generated scene point cloud are black and white.

Pre-calibration Configuration

If the robot supports Standard Interface or Master-control, please complete pre-calibration configuration according to the section Pre-calibration Configuration for automatic calibration in the Eye to Hand scenario.

Compared with the automatic calibration in the Eye to Hand scenario, the following operation is different. During the pre-calibration configuration in the Eye to Eye scenario, you need to select the Eye to eye radio button in the Select camera setup window.

../../_images/calib_preset_ete.png

If the robot does not support Standard Interface or Master-control, please complete pre-calibration configuration according to the section Pre-calibration Configuration for manual calibration in the Eye to Hand scenario (using the multiple random calibration board poses method).

Compared with the preceding calibration process, the following operations are different during the pre-calibration configuration in the Eye to Eye scenario:

  1. In the Select camera setup window, select the Eye to eye radio button.

    ../../_images/calib_preset_ete.png
  2. In the Select how to collect data window, select the Multiple random calibration board poses radio button.

    ../../_images/calib_preset_ete_random.png

Calibration Procedure

Connect to the Camera

  1. In the Connect to camera step, select the sub-camera to connect in the Detected cameras list, and then click the icon_1 button or double-click the camera entry to connect to it.

    ../../_images/connect_camera_ete.png
  2. Repeat the preceding step to connect to the main camera. After the main camera is connected, the master icon will be displayed before the camera ID.

    Tip

    To switch the main camera, select a camera, and then click the Set as main button.

  3. After the camera is connected, click the Capture once or Capture live button.

    ../../_images/image_capture_ete.png
  4. In the right Image viewer panel, ensure that the captured 2D image and depth map meet the calibration requirements and click the Next button on the bottom bar.

    Note

    If the captured image does not meet the calibration requirements, you need to open the Mech-Eye Viewer software to adjust the 2D and 3D scanning parameters and re-capture images. * In this step, the 2D image and depth map are captured only for the main camera. To confirm the effects of the images captured by the sub-camera, you can switch it to the main camera, and switch the original main camera back to the main camera after confirming.

Other Steps

If the robot supports Standard Interface or Master-control, please complete remaining steps of the calibration procedure according to the section Calibration Procedure for automatic calibration in the Eye to Hand scenario.

If the robot does not support Standard Interface or Master-control, please complete remaining steps of the calibration procedure according to the section Calibration Procedure for manual calibration in the Eye to Hand scenario (using the multiple random calibration board poses method).

Note

  • In the Collect images and poses step, the software will capture calibration images for the two cameras at the same time and collect the pose data. You can switch the camera in the Calibration image and pose list panel to view the calibration board images and calibration circle data collected for each camera.

  • In the Calculate camera parameters step, the software will calculate the extrinsic parameters for both cameras, and the pose relationship between the two cameras.

Confirm that the Calibration Accuracy Meets Requirements and Save Calibration Data

  1. In the Calculate camera parameters step, view the calibration error of point cloud in the right Point cloud viewer panel after the calibration calculation is complete.

    Note

    You can switch the camera in the Calibration image and pose list panel to view the error point cloud of different cameras.

  2. Find the error value with the 100% percentage to get the rough calibration accuracy.

  3. Confirm that the calibration accuracy meets the project requirements, and then click the Save button on the bottom bar.

  4. In the prompted Save Calibration Files dialog box, click the OK button to save the calibration result to the project folder.

Till now, the calibration process is completed. If you want to enhance the calibration accuracy, please refer to the section Calibration Result Check and Analysis.

Calculate Pose Relationship between Cameras from the Calibrated Extrinsic Parameters Directly

After calibrating the extrinsic parameters of the two cameras separately, you can use the Eye to Eye calibration procedure to calculate the pose relationship of the two cameras.

To do so, follow these steps:

  1. Open Mech-Vision, and click the Camera Calibration (Standard) button on the toolbar. The Configuration before Calibration window will be prompted.

  2. In the Select how to calibrate window, select the New calibration radio button, and then click the Next button.

    ../../_images/calib_preset_new.png
  3. In the Select calibration task window, select Hand-eye calibration for custom robot from the drop-down list box, specify the Robot Euler angle convention parameter, select the robot coordinate system type, and then click the Next button.

    ../../_images/calib_preset_select_robot_other.png
  4. In Select a robot type for calibration window, select a robot type among 6-axis robot, 4-axis robot (SCARA, Palletizer) or 5-axis robot or other types radio button, and then click the Next button.

    ../../_images/calib_preset_select_robot_type1.png
  5. In the Select camera setup window, select the Eye to eye radio button, and then click the Next button.

    ../../_images/calib_preset_ete.png
  6. In the Select how to collect data window, select the Use calibrated extrinsic parameters for calculation , choose two camera’s extrinsic parameter files, and then click the Calibrate button. The Calibration (Eye to Eye) window will be prompted.

    ../../_images/calib_preset_ete_calculate.png
  7. In the Connect to Camera window, find the camera to connect in the Detected Cameras list, and click icon_1 .

  8. Repeat the preceding step to connect to the second camera, and then click the Next button on the bottom bar.

  9. In the Calculate camera parameters step, select the Calculate rotation and translation separately checkbox, and then click the Calculate camera extrinsic parameters button.

    ../../_images/calcualte_extri_param_ete_quick.png

After the camera extrinsic parameters have been calculated, you can view the fused point cloud in the Point cloud viewer panel.

Check the Fusion Effect of Eye to Eye Calibration in a Mech-Vision Project

You can build a project as shown in the following figure. Note that the Trigger Control Flow Given No Output and Trigger Control Flow Given Output options in Execution Flags area should be selected.

../../_images/ete_project.png

Execute the single Step “Merge Data” to display the fused point cloud. The point cloud output after merging is the fused whole point cloud, as shown in the figure below. You can click the upper left corner View as Whole| 1 | 2 to switch point clouds.

../../_images/converged_poin_cloud.png