Connect Camera and Industrial PC¶
Connect Directly¶
Ethernet Cable: insert one end into the port on the IPC and the other into the LAN port on the camera.
Power Adapter: insert the connector into the DC 24V port and the plug into a power supply, as shown below.
When inserting the ethernet cable and power cable:
① Make sure the bump on the connector is aligned with the notch of the port.② Tighten the nut after inserting the cable.
Attention
If multiple cameras or IPCs need to be connected, a network switch can be used.
The PWR indicator light should turn on after the cables are connected. If the light is not on, please contact technical support.
The recommended tightening torque for the bolts is 16 N·m.
The DIN rail or the DIN rail power supply should be reliably grounded. If using multiple DIN rail power supplies, ensure enough distance in between when mounting.
DIN Rail Power Supply
When wiring the DIN rail power supply, wires of the power cable must be inserted to the corresponding input/output terminal block connectors, as shown above.
The AC power cable has three wires: L, N, and PE ().The 24 V DC power cable has three wires: V+, V- and PE ().
Hint
Please attach the plastic cover once you finish wiring to ensure the wires are isolated from each other.
Connect through a Network Switch¶
If multiple cameras or IPCs need to be connected, a network switch can be used, as shown below.