User Interface of Mech-Eye Viewer

This section introduces the user interface of Mech-Eye Viewer and provides descriptions of each button and option.

Camera List

When you open Mech-Eye Viewer, the Camera List is displayed, as shown below.

../../_images/device_finder_main.png

In this interface, you can view all the available cameras and their information, set camera IP address and connect to a camera.

Note

Once a camera is connected, you can’t return to this interface unless you disconnect from the camera. Therefore, if you need to change the camera IP address, please do so before connecting to the camera.

Camera Viewer

After the camera is successfully connected, the software will display the Camera Viewer interface, as shown below.

../../_images/main_view.png

This interface consists of the following parts:

  1. Menu Bar: save raw data, start virtual camera, open built-in tools, check software information, etc.

  2. Camera Toolbar: disconnect the camera, obtain and save images, and view logs.

  3. Image Display Area: display obtained 2D image, depth map, and point cloud.

  4. Parameter Panel: view and adjust parameters for image capturing, and save parameter groups for different purposes.

  5. Status Bar: display software and image capturing status. Use Previous and Next to switch between entries.


The following sections are detailed descriptions of each option in the above parts.

Camera Toolbar

Button

Function

icon_disconnect

Disconnect from the current camera.

icon_single_cap

Perform image capturing once, and display the obtained 2D image, depth map, and point cloud.

icon_continuous_cap

Continuously perform image capturing and display the last obtained 2D image, depth map, and point cloud.

icon_save

Save the last obtained 2D image, depth map, and/or point cloud.

icon_show_log

Display log(s).

Hint

For detailed information on the log, please refer to Log.

Image Display Area

This area displays the last obtained 2D image, depth map or point cloud.

Option

Description

2D Image

View the 2D image last obtained by the camera.

Depth Map

View the last generated depth map.

Point Cloud

View the last generated point cloud.

Parameter Panel

Note

It is recommended to maximize the interface of Mech-Eye Viewer for better display of components in the Parameter Panel.

Visibility

Visibility settings determine what and how parameters are displayed.

The drop-down menu options include Beginner and Expert. More parameters are available for adjustment in Expert mode. The default mode is Beginner. If the parameter adjustment in Beginner mode do not produce satisfactory data quality, please switch to Expert mode for finer tuning.

By default, all adjustable parameters in the selected visibility mode are expanded. You can use the following two icons to quickly expand or collapse all parameters.

  • icon_expand: expand all parameters.

  • icon_collapse: collapse all parameters.

Parameter Group

Parameter groups are fixed combinations of parameter values.

Two parameter groups come with the software: default and calib.

You can adjust the parameters according to your needs, and then save the combination as a parameter group for future use under similar conditions.

Selecting a parameter group from the drop-down menu quickly applies the saved values to the corresponding parameters.

Button

Function

icon_plus

Create a new parameter group.

icon_reduce

Delete the currently selected parameter group.

icon_rename

Rename the currently selected parameter group.

Save

Save the parameter values to the currently selected parameter group. Shortcut: Ctrl + S.

Reset

Reset the parameter values in the currently selected parameter group to default values.

Import

Import parameter groups (Not available when connected to a virtual camera).

Export

Export parameter groups (Not available when connected to a virtual camera).

Note

  • The default parameter group cannot be deleted.

  • It is recommended to create corresponding parameter groups for different applications/conditions.

Parameters

Parameters are divided into five categories: 3D Scanning, 2D Scanning, Point Cloud Processing, Depth Range, and 2D ROI.

For detailed information on adjusting parameters, please see Parameter Adjustment.

Hint

  • Click on a parameter’s name to view its definition, default value, etc.

  • Double-click on a parameter category to expand/collapse all the parameters in this category.

  • An asterisk (*) after a parameter’s name indicates that the current value of this parameter is not saved to the current parameter group.

Toolbar

If you checked Toolbar in the View menu, the toolbar is displayed between the Menu Bar and the Camera Toolbar.

The toolbar provides quick access to frequently used built-in tools. Exposure Assistant, Camera Firmware Update, and FOV Calculator are displayed by default.

You can display/hide the tools by clicking on More Tools. To display a tool in the Toolbar, check the box in front of it; to hide, uncheck the box. Click on OK to save the changes.

../../_images/tool_manager.png